Objectives To validate self-reported occupational loud noise exposure against expert evaluation of noise levels in a French case-control study on acoustic neuroma and to estimate the impact of exposure misclassification on risk estimation. Methods Noise levels were evaluated in 1006 jobs held by 111 cases and 217 population controls by an expert. Case-control differences in self-reporting were analyzed with logistic models. Sensitivity, specificity, positive and negative predictive values, and observed agreement of the self-reports were computed relative to the expert evaluation. They were used to calibrate the odds ratio (OR) between lifetime ever occupational loud noise exposure and the risk of acoustic neuroma, without adjustment for measurement error of the expert assessments. Results Cases reported noise levels in individual jobs closer to the expert assessment than controls, but the case-control difference was small for lifetime exposures. For expert-rated exposure of 80 dB(A), reporting of individual jobs by cases was more sensitive (54% in cases, 37% in controls), whereas specificity (91% in cases, 93% in controls) and observed agreement (82% in cases, 81% in controls) were similar. When lifetime exposure was considered, sensitivity increased (76% in cases, 65% in controls), while cases specificity decreased (84%). When these values were used to calibrate self-reports for exposure misclassification compared to expert evaluation at 80 dB(A), the crude OR of 1.7 was reduced to 1.3. Conclusions Despite the relatively accurate reporting of loud noise, the impact of the calibration on the OR was non-negligible.
机译:目的验证自我报告的职业大声噪声暴露对声神经瘤的法国病例对照研究中的噪声水平的专家评估,并估算暴露错误分类对风险估计的影响。方法在111例举行的1006个工作岗位和专家持有217名人口控制的工作中评估了噪声水平。用物流模型分析了自我报告的病例控制差异。相对于专家评估,计算敏感性,特异性,正负预测值,以及观察到自我报告的协议。它们用于校准终身职业大声噪声暴露和声神经瘤的风险之间的少数赔率比(或),而不会调整专家评估的测量误差。结果案件报告的个别工作中的噪音水平更接近专家评估而不是控制,但案件控制差异很小,以便终身曝光。对于80 dB(a)的专家率曝光,案例的报告更敏感(在案件中54%,对照组37%),而特异性(案件中91%,控制中93%)和观察到的协议( 82%的病例中的81%,对照有81%)是相似的。当考虑寿命暴露时,敏感性增加(病例中76%,对照65%),而病例特异性降低(84%)。与80dB(a)的专家评估相比,使用这些值进行校准以进行暴露错误分类时,将粗原或1.7降至1.3。结论尽管对大声噪音的报告相对准确,但校准对或不可忽视的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号