首页> 外文期刊>Analytical methods >Determination of chloride and nitrate in dimethyl carbonate using a column-switching ion chromatography system
【24h】

Determination of chloride and nitrate in dimethyl carbonate using a column-switching ion chromatography system

机译:用柱切换离子色谱系统测定碳酸二甲酯中氯化物中的硝酸盐

获取原文
获取原文并翻译 | 示例
           

摘要

Dimethyl carbonate (DMC) is widely used in solvents, fuels, monomers, and synthesis. The inorganic anions in DMC always have a big impact on product performance. Herein, improvement in the performance of the conventional column-switching technique and on-line elimination pretreatment system was achieved to automatically determine trace anions in DMC. In this study, a pretreatment column was applied to eliminate the DMC matrix on-line, and target anions were eluted from the pretreatment column and retained in the concentrator column. The collected anions were eventually separated in the analytical column using the column-switching technique. Eluent containing 100% acetonitrile was used to wash out DMC and regenerate the pretreatment column at the same time. A type of water-soluble solvent was added to the DMC samples before injection to help improve their solubility in the eluent, which was subsequently removed by extending the collection time in the concentration procedure. This method shows satisfactory linearity (R-2 >= 0.9977) in the range of 0.1-8.0 mg L-1. The detection limit based on the signal-to-noise ratio of 3 (S/N = 3) is 2.79-5.66 mg L-1. The recovery rate for the anions is 85.09-99.07%. Good reproducibility was obtained with relative standard deviations less than 4.03% by injecting standard solutions 6 times.
机译:碳酸二甲酯(DMC)广泛用于溶剂,燃料,单体和合成中。 DMC中的无机阴离子始终对产品性能产生了很大影响。这里,实现了传统柱切换技术和在线消除预处理系统的性能的改进,以便在DMC中自动地确定痕量阴离子。在该研究中,应用预处理柱以消除DMC基质在线,并从预处理柱洗脱靶阴离子并保留在浓缩器柱中。最终使用列切换技术最终在分析柱中分离收集的阴离子。含有100%乙腈的洗脱液用于洗脱DMC并同时再生预处理塔。在注射之前,将一种水溶性溶剂加入到DMC样品中,以帮助改善洗脱液中的溶解度,随后通过在浓缩过程中延长收集时间来除去。该方法显示令人满意的线性度(R-2> = 0.9977),其范围为0.1-8.0mg L-1。基于3(S / N = 3)的信噪比的检测限为2.79-5.66mg L-1。阴离子的回收率为85.09-99.07%。通过注射标准溶液6次,通过相对标准偏差获得良好的再现性。

著录项

  • 来源
    《Analytical methods》 |2017年第19期|共5页
  • 作者单位

    Zhejiang Univ Dept Chem Xixi Campus Hangzhou 310028 Zhejiang Peoples R China;

    Zhejiang Univ Dept Chem Xixi Campus Hangzhou 310028 Zhejiang Peoples R China;

    Zhejiang Shuren Univ Coll Biol &

    Environm Engn Hangzhou 310015 Zhejiang Peoples R China;

    Zhejiang Univ Dept Chem Xixi Campus Hangzhou 310028 Zhejiang Peoples R China;

    Zhejiang Univ Dept Chem Xixi Campus Hangzhou 310028 Zhejiang Peoples R China;

    Zhejiang Univ Dept Chem Xixi Campus Hangzhou 310028 Zhejiang Peoples R China;

    Zhejiang Univ Dept Chem Xixi Campus Hangzhou 310028 Zhejiang Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 分析化学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号