Objective: Cardiac arrhythmias can be serious and life threatening, and can impose a significant burden on healthcare systems. Recent technological advances in ambulatory electrocardiogram recorders have led to the development of unobtrusive wearable biosensors which allow physicians to study patients' continuous cardiac rhythm data collected over multiple weeks. The objective of this systematic literature review was to summarize evidence on the clinical effectiveness of the Zio(1) patch, a long-term, continuous, uninterrupted cardiac monitoring system. Methods: Findings from searches of MEDLINE, Embase and the Cochrane Central Register of Controlled Trials, as well as grey literature, were screened by two reviewers to identify studies reporting cardiac arrhythmia detection outcomes among patients monitored with Zio for an intended duration >= 7 days. Results: Twenty-three publications (22 unique studies) were identified. The unweighted mean wear time was 10.4 days (median ranging from 5 to 14 days). The rate of arrhythmia detection increased with monitoring durations >48 h and continued to increase beyond 7 days of monitoring. Across the 22 studies, unweighted mean detection rates for atrial fibrillation (AF; n = 15), supraventricular tachycardia or supraventricular ectopy (n = 15), and ventricular tachycardia (n = 15) were 12.2%, 45.5% and 17.3%, respectively. Unweighted mean detection rates for chronic/sustained AF (n = 5) and paroxysmal AF (n = 5) were 5.6% and 23.3%, respectively. Conclusion: Findings from the review suggest that long-term, continuous, uninterrupted monitoring with Zio results in longer patient wear times and higher cardiac arrhythmia detection rates compared with outcomes reported in previous reviews of short-duration (24-48 h) cardiac rhythm recording studies.
机译:目的:心律失常可能是严重的,危及生命,并可能对医疗保健系统施加重大负担。最近的动态心电图记录器的技术进步导致了不显眼的可穿戴生物传感器的发展,允许医生研究患者的连续心律节奏数据在多周内收集的患者。该系统文献综述的目的是总结有关Zio(1)补丁,长期,连续,不间断的心脏监测系统临床效果的证据。方法:由两次审查员筛选出版物,Embase和Cochrane中央登记,以及灰色文学的研究结果,筛查了在预期持续时间(预定持续时间)监测的患者中的心律失常检测结果的研究报告的研究报告= 7天。结果:确定了二十三个出版物(22项独特的研究)。未加权的平均磨损时间为10.4天(5至14天的中位数范围)。心律失常检测率随监测持续时间的增加> 48小时,并继续增加7天的监测。在22项研究中,针对心房颤动的未加权平均检测率(AF; N = 15),髁上心动过速或髁上射伤(n = 15)和心室心动过速(n = 15)分别为12.2%,45.5%和17.3% 。慢性/持续AF(n = 5)和阵发性AF(n = 5)的未加权平均检测率分别为5.6%和23.3%。结论:审查中的调查结果表明,长期,连续,不间断的监测,ZIO导致较长的患者磨损时间和较高的心律失常检测率与先前的短期内报告的结果(24-48小时)心律节奏录制报告学习。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号