首页> 外文期刊>Computers in Biology and Medicine >Estimation of core body temperature from skin temperature, heat flux, and heart rate using a Kalman filter
【24h】

Estimation of core body temperature from skin temperature, heat flux, and heart rate using a Kalman filter

机译:使用卡尔曼滤波器估计皮肤温度,热通量和心率的核心体温

获取原文
获取原文并翻译 | 示例
           

摘要

Core body temperature (TC) is a key physiological metric of thermal heat-strain yet it remains difficult to measure non-invasively in the field. This work used combinations of observations of skin temperature (TS), heat flux (HF), and heart rate (HR) to accurately estimate TCusing a Kalman Filter (KF). Data were collected from eight volunteers (age 22?±?4?yr, height 1.75?±?0.10?m, body mass 76.4?±?10.7?kg, and body fat 23.4?±?5.8%, mean?±?standard deviation) while walking at two different metabolic rates (~350 and ~550?W) under three conditions (warm: 25?°C, 50% relative humidity (RH); hot-humid: 35?°C, 70% RH; and hot-dry: 40?°C, 20% RH). Skin temperature and HF data were collected from six locations: pectoralis, inner thigh, scapula, sternum, rib cage, and forehead. Kalman filter variables were learned via linear regression and covariance calculations between TCand TS, HF, and HR. Root mean square error (RMSE) and bias were calculated to identify the best performing models. The pectoralis (RMSE 0.18?±?0.04?°C; bias ?0.01?±?0.09?°C), rib (RMSE 0.18?±?0.09?°C; bias ?0.03?±?0.09?°C), and sternum (RMSE 0.20?±?0.10?°C; bias ?0.04?±?0.13?°C) were found to have the lowest error values when using TS, HF, and HR but, using only two of these measures provided similar accuracy.
机译:核心体温(Tc)是热敏菌株的关键生理度量,但它仍然难以在该领域中测量非侵入性。这项工作使用了皮肤温度(TS),热通量(HF)和心率(HR)的观察组合,以准确估计了Kalman滤波器(KF)。从八个志愿者收集数据(22岁?±4?Yr,高度1.75?±0.10?M,体积76.4?±10.7?kg和体脂23.4?±5.8%,平均值?标准偏差)在三种条件下以两种不同的代谢速率行走(〜350和〜550?w)(温暖:25℃,50%相对湿度(RH);热湿:35?°C,70%RH;和热干:40℃,20%RH)。从六个地点收集皮肤温度和HF数据:Pectoralis,内部大腿,肩胛骨,胸骨,肋骨和额头。 Kalman滤波器变量通过TCAND TS,HF和HR之间的线性回归和协方差计算学习。计算均均方误差(RMSE)和偏置以识别最佳性能的模型。 Pectoralis(Rmse 0.18?±0.04?°C;偏压?0.01?±0.09℃),肋(Rmse 0.18?±0.09°C;偏见?0.03?±0.09°C),和胸骨(RMSE 0.20?±0.10?°C;偏置Δ0.04?±0.13°C)使用TS,HF和HR时具有最低误差值,但是,只使用其中两种测量提供了类似的准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号