Non-invasive, multi-parameter methods to estimate core body temperature offer several advantages for monitoring thermal strain, although further work is required to identify the most relevant predictor measures. This study aimed to compare the validity of an existing and two novel multi-parameter rectal temperature prediction models. Thirteen healthy male participants (age 30.9 ± 5.4 years) performed two experimental sessions. The experimental procedure comprised 15 min baseline seated rest (23.2 ± 0.3°C, 24.5 ± 1.6% relative humidity), followed by 15 min seated rest and cycling in a climatic chamber (35.4 ± 0.2°C, 56.5 ± 3.9% relative humidity; to +1.5°C or maximally 38.5°C rectal temperature, duration 20–60 min), with a final 30 min seated rest outside the chamber. In session 1, participants exercised at 75% of their heart rate maximum (HR max) and wore light athletic clothing (t-shirt and shorts), while in session 2, participants exercised at 50% HR max, wearing protective firefighter clothing (jacket and trousers). The first new prediction model, comprising the input of 18 non-invasive measures, i.e., insulated and non-insulated skin temperature, heat flux, and heart rate (“Max-Input Model”, standard error of the estimate [SEE] = 0.28°C, R2 = 0.70), did not exceed the predictive power of a previously reported model which included six measures and no insulated skin temperatures (SEE = 0.28°C, R2 = 0.71). Moreover, a second new prediction model that contained only the two most relevant parameters (heart rate and insulated skin temperature at the scapula) performed similarly (“Min-Input Model”, SEE = 0.29, R2 = 0.68). In conclusion, the “Min-Input Model” provided comparable validity and superior practicality (only two measurement parameters) for estimating rectal temperature versus two other models requiring six or more input measures.
机译:尽管需要进一步的工作来确定最相关的预测指标,但估计核心体温的非侵入式多参数方法仍具有监测热应变的多个优势。这项研究旨在比较现有的和两个新颖的多参数直肠温度预测模型的有效性。 13名健康的男性参与者(年龄30.9±5.4岁)进行了两次实验。实验程序包括15分钟的基线就座休息(23.2±0.3°C,24.5±1.6%相对湿度),随后15分钟的就座休息并在气候室(35.4±0.2°C,56.5±3.9%相对湿度)中循环;最高至+ 1.5°C或最高38.5°C的直肠温度,持续时间20–60分钟),最后30分钟在腔室外休息。在第1课中,参与者以最大心率(HR max)的75%进行运动,穿着轻便的运动服(T恤和短裤),而在第2课中,参与者以HR max%进行运动,穿着消防员的防护服(夹克)和裤子)。第一个新的预测模型,包括18种非侵入性测量的输入,即绝缘和非绝缘的皮肤温度,热通量和心率(“最大输入模型”,估计的标准误差[SEE] = 0.28 °C,R 2 = 0.70),没有超过先前报告的模型的预测能力,该模型包括六种措施并且没有绝缘的皮肤温度(SEE = 0.28°C,R 2 = 0.71)。此外,第二个新预测模型只包含两个最相关的参数(肩rate骨的心率和绝热皮肤温度),其执行情况类似(“最小输入模型”,SEE = 0.29,R 2 = 0.68)。总之,“最小输入模型”与其他两个需要六个或更多输入测量值的模型相比,在估计直肠温度方面具有可比的有效性和优越的实用性(仅两个测量参数)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号