Background and purpose Hydroxyapatite (HA) coating is believed to improve bone-implant ingrowth and long-term survival of prostheses. Recent studies, however, have challenged this view. Furthermore, HA particles may produce third-body wear and initiate aseptic loosening of implants. We report the performance of HA- and porous-coated acetabular cups in a prospective randomized trial. Methods This was an 8-year follow-up study of our previously published prospective randomized study to compare clinical outcomes, survival, periprosthetic bone mineral density, migration, and wear rates of HA- and porous-coated acetabular cups. Dual X-ray absorptiometry (DXA) and Ein Bild Roentgen Analyse (EBRA) measurements were used. 100 patients who underwent unilateral cementless total hip arthroplasty were randomized to either porous-coated cups or HA-coated cups. Patients were examined preoperatively and at 3, 6, and 9 months, and also 1, 3, and 8 years after surgery. 81 patients were available for 8-year follow-up, 40 with porous-coated cups and 41 with HA-coated cups. Results Age, sex, bone mineral density, and clinical results (Harris hip score) were similar in the 2 groups. The survival, wear, and migration patterns of the cups were also similar in both groups. The results of periprosthetic bone mineral density scans in region of interest 2 was in favor of the porous-coated cups, but there were no differences between the 2 groups in all the remaining regions of interest. Interpretation HA coating had no statistically significant effect on clinical results, survival, wear, or migration at the 8-year follow-up.
机译:背景和目的羟基磷灰石(HA)涂层被认为可以改善骨植入物向内生长和假体的长期存活。但是,最近的研究对这一观点提出了挑战。此外,HA颗粒可能会导致第三者身体磨损并引发植入物的无菌松动。我们在一项前瞻性随机试验中报告了HA涂层和多孔涂层髋臼杯的性能。方法这是一项8年的随访研究,对我们先前发表的前瞻性随机研究进行了比较,以比较HA涂层和多孔涂层髋臼杯的临床结局,生存率,假体周围骨矿物质密度,迁移率和磨损率。使用双X射线吸收法(DXA)和Ein Bild伦琴分析(EBRA)测量。 100例行单侧非骨水泥全髋关节置换术的患者被随机分为多孔涂层杯或HA涂层杯。术前,术后3、6、9个月以及术后1,3,8年对患者进行了检查。 81位患者可进行8年随访,其中40位使用多孔涂层杯,41位使用HA涂层杯。结果两组的年龄,性别,骨矿物质密度和临床结果(Harris髋关节评分)相似。两组的生存,磨损和迁移模式也相似。感兴趣区域2中的假体周围骨矿物质密度扫描的结果有利于多孔涂层杯,但在其余所有感兴趣区域中,两组之间没有差异。解释在8年的随访中,HA涂层对临床结果,存活率,磨损或迁移没有统计学意义的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号