首页> 外文期刊>Clinical neurophysiology >Comparison of visual evoked potential monitoring during spine surgeries under total intravenous anesthesia versus balanced general anesthesia
【24h】

Comparison of visual evoked potential monitoring during spine surgeries under total intravenous anesthesia versus balanced general anesthesia

机译:在总静脉内麻醉中脊柱手术期间视觉诱发潜在监测的比较与平衡全身麻醉

获取原文
获取原文并翻译 | 示例
           

摘要

Highlights ? SightSaver? visual stimulator is a reliable method for intraoperative visual evoked potential monitoring. ? Total intravenous anesthesia (TIVA) leads to higher VEP amplitude and shorter latencies, compared to balanced general anesthesia. ? TIVA is the most efficient anesthesia regimen for monitoring VEP during prone spinal surgeries. Abstract Objective To determine the comparison of its clinical utility and safety profile for visual evoked potential (VEP) monitoring during prone spine surgeries under total intravenous anesthesia (TIVA) versus balanced general anesthesia using the SightSaver? visual stimulator. Methods The protocol was designed as a pilot, single center, prospective, randomized, and double-arm study. Subjects were randomized to receive either TIVA or balanced general anesthesia. Following induction and intubation, 8 electrodes were placed subcutaneously to collect VEP recordings. The SightSaver? visual stimulator was placed on the subject’s scalp before prone positioning. VEP waveforms were recorded every 30 min and assessed by a neurophysiologist throughout the length of surgery. Results A total of 19 subjects were evaluated and VEP waveforms were successfully collected. TIVA group showed higher amplitude and lower latency than balanced anesthesia. Conclusions Our data suggested that TIVA is associated with higher VEP amplitude and shorter latencies than balanced general anesthesia; therefore, TIVA could be the most efficient anesthesia regimen for VEP monitoring. Significance The findings help to better understand the effect of different anesthesia regimens on intra-operative VEP monitoring. ]]>
机译:强调 ?观光兽?视觉刺激器是用于术中视觉诱发电位监测的可靠方法。还与平衡的全身麻醉相比,总静脉内麻醉(TIVA)导致较高的VEP幅度和更短的延迟。还Tiva是在易于脊柱手术期间监测VEP的最有效的麻醉方案。摘要目的是确定其临床兴起潜在(VEP)监测的临床实用性和安全型材的比较,静脉内麻醉总静脉内麻醉(TIVA)与使用观光物的平衡全身麻醉?视觉刺激器。方法该协议被设计为试点,单一中心,前瞻性,随机和双臂学习。受试者随机接受Tiva或平衡的全身麻醉。在感应和插管之后,皮下放置8个电极以收集VEP录制。观光游客?在易于定位之前,可视刺激器被放置在受试者的头皮上。每30分钟记录VEP波形,并通过整个手术的长度评估神经生理学家。结果评估了总共19个受试者,并成功收集了VEP波形。 Tiva集团表现出比平衡麻醉更高的幅度和更低的延迟。结论我们的数据表明,TIVA与较高的VEP幅度和较短的延迟相关,而不是平衡的全身麻醉;因此,Tiva可能是Vep监测最有效的麻醉方案。研究结果有助于更好地了解不同麻醉方案对术中vep监测的影响。 ]]>

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号