PURPOSE: To evaluate the efficacy of added shear wave elastography (SWE) in breast screening for women with results inconsistent between mammography and conventional ultrasounds (US). MATERIALS AND METHODS: The study consisted of 282 pathologically proven breast lesions. The cancer probability from screening by mammography and conventional US were scored using Breast Imaging Reporting and Data System (BI-RADS). Elastography was used to re-evaluate inconsistent conventional US and mammography results. The diagnostic performance of conventional US, mammography, and Combined conventional clinical imaging and SWE was compared. The clinicopathological features of all breast cancer patients with inconsistent (and consistent) conventional US and mammography findings were compared. RESULT: Finally, 147 lesions were confirmed benign and 135 were malignant. The AUC of Combined conventional clinical imaging plus elastography imaging (0.870) was significantly higher than mammography (0.735, p ??0.001) or conventional US (0.717, p ??0.001) alone. Among the 135 breast cancers, 79 of the conventional US and mammography findings were consistent and 56 were inconsistent. Younger age(50y) (p ?=?0.035), non-invasive (p ?=?0.037), smaller size (p ?=?0.002) and negative lymph node status (p ?=?0.026) were significantly associated with inconsistent findings. CONCLUSION: The added SWE in breast screening when inconsistent results from mammography and conventional US occurred is necessary and effective.
机译:目的:评估乳房X线照相术和传统超声(US)之间的患者乳房筛选中添加的剪切波弹性造影(SWE)的疗效。材料和方法:该研究包括282个病理证明乳房病变。使用乳房成像报告和数据系统(BI-RAD),通过乳房X线照相术和常规筛选癌症概率。弹性造影用于重新评估常规的常规US和乳房X线摄影结果。比较了常规US,乳房X线照相术和常规临床影像和SWE的诊断性能。比较了所有乳腺癌患者的临床病理学特征(和一致)常规的美国和乳房X线摄影结果。结果:最后,确认了147个病变良性,135名恶性肿瘤。组合常规临床成像加弹性摄像(0.870)的AUC显着高于乳房X线照相术(0.735,p≤0.001)或常规US(0.717,p≤0.001)。在135个乳腺癌中,常规美国和乳房X线摄影结果中的79个是一致的,56个不一致。较小的年龄(p?= 0.035),无侵入性(p?= 0.037),尺寸较小(p?= 0.002)和阴性淋巴结状态(p?= 0.026)显着相关有不一致的调查结果。结论:乳腺筛选中添加的SWE在乳房X线照相术和常规美国发生不一致的情况下是必要的,有效的。

著录项

  • 来源
  • 作者单位

    Department of Medical Ultrasound Shanghai Tenth People’s Hospital Tongji University School of;

    c Department of Radiology Shanghai Tenth People’s Hospital Tongji University School of Medicine;

    b Ultrasound Research and Education Institute Tongji University School of Medicine Shanghai China;

    c Department of Radiology Shanghai Tenth People’s Hospital Tongji University School of Medicine;

    b Ultrasound Research and Education Institute Tongji University School of Medicine Shanghai China;

    b Ultrasound Research and Education Institute Tongji University School of Medicine Shanghai China;

    c Department of Radiology Shanghai Tenth People’s Hospital Tongji University School of Medicine;

    c Department of Radiology Shanghai Tenth People’s Hospital Tongji University School of Medicine;

    b Ultrasound Research and Education Institute Tongji University School of Medicine Shanghai China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 心脏、血管(循环系)疾病;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号