首页> 外文期刊>Catheterization and cardiovascular interventions: Official journal of the Society for Cardiac Angiography & Interventions >In vitro flow and optical coherence tomography comparison of two bailout techniques after failed provisional stenting for bifurcation percutaneous coronary interventions
【24h】

In vitro flow and optical coherence tomography comparison of two bailout techniques after failed provisional stenting for bifurcation percutaneous coronary interventions

机译:在经皮冠状动脉干预的分叉临时支架失败后的两个救助技术的体外流程和光学相干断层扫描比较

获取原文
获取原文并翻译 | 示例

摘要

Objectives To evaluate, in vitro, SB stenting techniques after failed provisional stenting. We aimed to compare flows and stent strut apposition of T and protrusion (TAP) versus Reversed String (RS) techniques using a flow simulator, optical coherence tomography (OCT) using silicon bifurcation phantoms with different bifurcation angulations. Background While bifurcation coronary artery stenoses are preferably treated with provisional T-stenting strategy, the preferred bailout two stents technique to treat the side branch remains unclear. Methods and results Eleven 30 degrees-angle and ten 60 degrees-angle bifurcation phantoms were used. After performing provisional stenting, TAP and RS techniques were compared in six phantoms with 30 degrees and five with 60 degrees angles. Flow measurement was performed using absolute coronary flow and particle image velocimetry techniques. Strut apposition was evaluated using OCT. Flow analyses showed that disturbed flow regions were observed in the vicinity of floating struts protruded into the lumen both regardless of TAP and RS techniques. OCT analysis showed a higher proportion of floating struts protruding into the main branch with TAP compared to RS, respectively (13% vs. 1%; P 0.001) in both angles. Conclusions RS reduces the proportion of floating struts protruding into the main branch compared to TAP, at comparable flow rates. Clinical studies are needed to evaluate feasibility and potential clinical benefit of this technique.
机译:在临时支架失败后,在体外评估,体外,SB支架技术。我们的目标是使用流量模拟器,使用流动模拟器,光学相干性断层扫描(OCT)与具有不同分叉角度的硅分叉模拟,比较T和突起(TAP)的流量和突起(RS)技术的流量和支柱。背景技术虽然优选用临时T-支架策略处理分叉冠状动脉缩放,但是优选的救助部门治疗侧支分支仍然尚不清楚。方法和结果110度和十个60度分叉映射的方法。在进行临时支架之后,将Tap和RS技术在六个幻影中比较,30度,五个,具有60度角度。使用绝对冠状动脉和颗粒图像测速技术进行流量测量。使用OCT评估Strut Sountion。流动分析表明,无论水龙头和RS技术如何,在浮动支柱附近观察到干扰的流动区域。 OCT分析显示突出的浮动支柱比例突出到主要分支中,分别在两个角度下分别与Rs相比(13%vs. <0.001)相比。结论RS减少了与Tap,在可比流速下突出到主要分支中的浮动支柱的比例。需要临床研究来评估该技术的可行性和潜在的临床效益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号