...
首页> 外文期刊>Biosensors & Bioelectronics: The International Journal for the Professional Involved with Research, Technology and Applications of Biosensers and Related Devices >Development of surface plasmon resonance imaging for detection of Acidovorax avenae subsp. citrulli (Aac) using specific monoclonal antibody
【24h】

Development of surface plasmon resonance imaging for detection of Acidovorax avenae subsp. citrulli (Aac) using specific monoclonal antibody

机译:表面等离振子共振成像技术的发展,用于检测酸单胞菌亚种。 citrulli(Aac)使用特异性单克隆抗体

获取原文
获取原文并翻译 | 示例
           

摘要

An immunosensor based on surface plasmon resonance imaging (SPR imaging) using a specific monoclonal antibody 11E5 (MAb 11E5) was developed for the detection of the seed-borne bacterium Acidovorax avenae subsp. citrulli (Aac), which causes fruit blotch in watermelons and cantaloupes, and compared to the conventional ELISA technique. The 1:40 mixed self-assembled monolayer (mixed SAM) surface was used for the immobilized MAb 11E5 on sensor surface for the detection of Aac. Both whole cells and broken cells of Aac were tested by using direct and sandwich detection assay. The limit of detection (LOD) of Aac using the SPR imaging technique and a direct detection assay was 10~6cfu/ml and a subsequent amplification of the SPR signal using a polyclonal antibody (PAb) lowered the LOD to 5×10~5cfu/ml. The LOD for the ELISA technique was 5×10~4cfu/ml for the detection of Aac, which was slightly better than that for the SPR technique. However, the sensor surface based on SPR imaging offered a major advantage in terms of surface regeneration, allowing at least five cycles with a shorter time assay, multi-channel analysis with an application on multiplex detection, and an ease of the surface usage for the detection of Aac in the naturally infected plant. The surface was tested against the naturally infected sample and showed good selectivity toward the Aac bacteria.
机译:开发了一种基于表面等离子体共振成像(SPR成像)的免疫传感器,使用特定的单克隆抗体11E5(MAb 11E5)来检测种子传播的细菌Acidovorax avenae亚种。 citrulli(Aac),可引起西瓜和哈密瓜的水果斑点,并与常规ELISA技术进行了比较。将1:40混合的自组装单层(混合SAM)表面用于传感器表面上固定的MAb 11E5,以检测Aac。通过使用直接和夹心检测测定法测试Aac的全细胞和破碎细胞。使用SPR成像技术和直接检测测定法对Aac的检出限(LOD)为10〜6cfu / ml,随后使用多克隆抗体(PAb)扩增SPR信号将LOD降至5×10〜5cfu / ml毫升ELISA技术的LOD检测Aac的LOD为5×10〜4cfu / ml,比SPR技术略好。但是,基于SPR成像的传感器表面在表面再生方面提供了一个主要优势,允许至少五个周期进行更短的时间测定,在多路检测中应用多通道分析,并且易于进行表面检测。在自然感染的植物中检测Aac。用天然感染的样品对表面进行测试,并显示出对Aac细菌的良好选择性。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号