摘要

Time-of-flight (ToF) performances of large area diamond detectors based on polycrystalline samples of dimensions 20 mm x 20 mm and thickness of 0.3 mm are presented. The devices that feature segmented Cr/Au electrodes in a sandwich configuration were irradiated with a heavy ions Au-197 beam of 1 GeV u(-1) showing, when mounted with a separation distance of 2 cm, a ToF resolution (sigma) over bar of 37.5 ps averaged on 16 strip pairs. When ToF measurements were performed over a particle path of 30 m, a resolution sigma of 45 ps was achieved. The detectors were mounted on high-vacuum compatible printed circuit boards (PCBs) with integrated processing electronics. This is the first time that ToF measurements have been performed using integrated electronics with such a large separation distance between the diamond detectors.
机译:提出了基于20mm×20mm的多晶样品的大面积金刚石探测器的飞行时间(TOF)的性能,厚度为0.3mm。 用1 GEV U(-1)的重离子AU-197梁照射夹层配置中的分段CR / AU电极的装置,其显示在分离距离2cm的分离距离时,TOF分辨率(Sigma)结束 37.5 PS的棒平均为16条带对。 当在30μm的颗粒路径上进行TOF测量时,实现了45 ps的分辨率sigma。 探测器安装在具有集成处理电子设备的高真空兼容印刷电路板(PCB)上。 这是第一次使用集成电子器件进行TOF测量,其中金刚石探测器之间具有如此大的分离距离。