首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Determination of of steviol glycosides in commercial extracts of Stevia rebaudiana and sweeteners by ultra-high performance liquid chromatography Orbitrap mass spectrometry
【24h】

Determination of of steviol glycosides in commercial extracts of Stevia rebaudiana and sweeteners by ultra-high performance liquid chromatography Orbitrap mass spectrometry

机译:用超高效液相色谱法测绘甜菊酸甜度的商业提取物中甜菊糖糖苷的测定

获取原文
获取原文并翻译 | 示例
           

摘要

Stevia rebaudiana extracts are used as sweeteners in several countries worldwide. Several extracts of diverse composition are available on the market, and their taste depends on the contents of the various steviol-glycosides This study presents an accurate method for the qualitative and quantitative determination of steviol glycosides in 40 Stevia extracts, 7 sweeteners and 3 Stevia-sweetened beverages by a UHPLC coupled to an Orbitrap mass spectrometer. The sub-2 mu m amide column provided the separation of all the target analytes in a run time of 30 min with high resolution. The effect of different eluent compositions on the ionisation efficiency of the steviol glycosides was studied. The optimal ionisation conditions were achieved in negative mode using 0.05% formic acid. Under this condition, adducts were not found, [M-H](-) were the main ions and the spontaneous loss of a glucose residue at C19 was reduced. The %RSD for intra- and inter-day precision for all eleven analytes varied from 2.1 to 4.2% and 3.0-5.1%, respectively. The recoveries from spiked Stevia extract samples were greater than 95% for all analytes. Rebaudioside A was the most abundant, ranging from 23 to 102%. Nine Stevia extracts and one drink were not compliant with the European Regulation. Isosteviol was under the LOD in all samples and steviol was found in four samples in quantities in the range 0.01-0.03%. (C) 2018 Elsevier B.V. All rights reserved.
机译:史蒂维亚雷大·劳坦提取物在全球几个国家使用作为甜味剂。市场上有几种不同组合物的提取物,它们的味道取决于各种甜蜜糖苷的内容本研究呈现了40例甜叶菊提取物,7次甜味剂和3个甜叶菊的定性和定量测定甜菊糖糖苷的定性和定量测定的准确方法通过UHPLC耦合到侧面光谱仪的甜味饮料。亚2μm酰胺柱提供了高分辨率30分钟的运行时间中所有靶分析物的分离。研究了不同洗脱液组合物对甜叶醇糖苷的电离效率的影响。使用0.05%甲酸在负模式下实现最佳电离条件。在这种情况下,未发现加合物,[M-H]( - )是主要离子,并且在C19处的葡萄糖残基的自发性损失降低。所有11分析物的含量和日内精度的%RSD分别不同于2.1%至4.2%和3.0-5.1%。所有分析物的尖刺甜叶菊提取物样品的回收率大于95%。 Rebaudioside A最丰富,范围从23到102%。九甜度提取物和一杯饮料不符合欧洲法规。 Isosteviol在所有样品中的LOD下面,并且在四个样品中发现了甜蜜,其数量范围为0.01-0.03%。 (c)2018年elestvier b.v.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号