首页> 外文期刊>Physics in medicine and biology. >A method to incorporate the effect of beam quality on image noise in a digitally reconstructed radiograph (DRR) based computer simulation for optimisation of digital radiography
【24h】

A method to incorporate the effect of beam quality on image noise in a digitally reconstructed radiograph (DRR) based computer simulation for optimisation of digital radiography

机译:一种在数字射线照相中优化的基于数字重建射线照片(DRR)计算机仿真中的梁质量对图像噪声效果的方法。

获取原文
获取原文并翻译 | 示例
       

摘要

The use of computer simulated digital x-radiographs for optimisation purposes has become widespread in recent years. To make these optimisation investigations effective, it is vital simulated radiographs contain accurate anatomical and system noise. Computer algorithms that simulate radiographs based solely on the incident detector x-ray intensity ('dose') have been reported extensively in the literature. However, while it has been established for digital mammography that x-ray beam quality is an important factor when modelling noise in simulated images there are no such studies for diagnostic imaging of the chest, abdomen and pelvis. This study investigates the influence of beam quality on image noise in a digital radiography (DR) imaging system, and incorporates these effects into a digitally reconstructed radiograph (DRR) computer simulator. Image noise was measured on a real DR imaging system as a function of dose (absorbed energy) over a range of clinically relevant beam qualities. Simulated 'absorbed energy' and 'beam quality' DRRs were then created for each patient and tube voltage under investigation. Simulated noise images, corrected for dose and beam quality, were subsequently produced from the absorbed energy and beam quality DRRs, using the measured noise, absorbed energy and beam quality relationships. The noise images were superimposed onto the noiseless absorbed energy DRRs to create the final images. Signal-to-noise measurements in simulated chest, abdomen and spine images were within 10% of the corresponding measurements in real images. This compares favourably to our previous algorithm where images corrected for dose only were all within 20%.
机译:计算机模拟数字X-Xadichroys用于优化目的近年来普遍存在。为了使这些优化研究有效,它是重要的模拟射线照片,含有精确的解剖和系统噪声。在文献中,已经在文献中举报了基于入射检测器X射线强度(“剂量”)的计算机算法。然而,虽然已经建立了数字乳房X线摄影,但是X射线波束质量是在模拟图像中建模噪声的重要因素,但没有这样的研究胸部,腹部和骨盆的诊断成像。本研究调查了光束质量对数字射线照相(DR)成像系统中的图像噪声的影响,并将这些效应结合到数字重建的射线照片(DRR)计算机模拟器中。在真实DR成像系统上测量图像噪声作为一系列临床相关光束质量的剂量(吸收能量)的函数。然后,为每个患者和管电压创建模拟的“吸收能量”和“光束质量”DRR。随后使用测量的噪声,吸收能量和光束质量关系,随后从吸收的能量和光束质量DRR产生模拟噪声图像。噪声图像被叠加到无噪声的吸收能量DRR上以产生最终图像。模拟胸部,腹部和脊柱图像中的信号 - 噪声测量在真实图像中相应测量的10%以内。这对我们以前的算法有利地进行了比较,其中校正剂量的图像仅在20%以内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号