...
首页> 外文期刊>Journal of Agricultural and Food Chemistry >Ultrarapid Quantitation of Maize Proteins by Perfusion and Monolithic Reversed-Phase High-Performance Liquid Chromatography
【24h】

Ultrarapid Quantitation of Maize Proteins by Perfusion and Monolithic Reversed-Phase High-Performance Liquid Chromatography

机译:通过灌注和整体反相高效液相色谱法对玉米蛋白进行超快速定量

获取原文
获取原文并翻译 | 示例
           

摘要

The main objective of this study was to develop a new methodology alternative to the classical Kjeldahl analysis for determining maize proteins in maize products and seeds. For that purpose, two different chromatographic methodologies using perfusion and monolithic stationary phases, both enabling rapid separations of maize proteins, were investigated. Due to the difficulty to find suitable standards for this type of analysis, three different maize products were initially tested as proteins standards: zein F4000, corn gluten meal, and maize flour. Different figures of merit (i.e., linearity, correlation coefficient, precision, limits of detection and quantitation), as well as the presence of matrix inferences, were investigated. The results obtained for the different chromatographic stationary phases and protein standards were compared in order to select the most suitable analytical conditions. Despite both perfusion and monolithic methodologies resulting, in general, as appropriate for the quantitation of maize proteins, the highest reduction of analysis time and lowest detection and determination limits provided by perfusion methodology enabled to select this one as the method of choice for the quantitation of maize proteins. Regarding the different protein standards studied in this work, in general the best results were obtained using the zein standard. Compared to Kjeldahl methodology, perfusion chromatography yields total protein contents in shorter analysis time while enabling the separation of the different kinds of proteins. Due to the high diversity and complexity of industrial maize products, the proposed chromatographic method could be a very useful tool for their routine analysis.
机译:这项研究的主要目的是开发一种替代传统凯氏定氮法的新方法,用于确定玉米产品和种子中的玉米蛋白。为此,研究了使用灌注和整体固定相的两种不同的色谱方法,均能快速分离玉米蛋白。由于难以找到适合此类分析的标准品,因此最初测试了三种不同的玉米产品作为蛋白质标准品:玉米蛋白F4000,玉米蛋白粉和玉米粉。研究了不同的品质因数(即线性,相关系数,精度,检测和定量限)以及存在矩阵推论。比较了不同色谱固定相和蛋白质标准品获得的结果,以选择最合适的分析条件。尽管通常采用灌流和整体方法,但对于玉米蛋白的定量分析还是合适的,但通过灌流方法提供的分析时间的缩短和最低的检测和测定限度,使该方法成为选择玉米定量方法的最佳选择。玉米蛋白。关于这项工作中研究的不同蛋白质标准品,通常使用玉米蛋白标准品可获得最佳结果。与凯氏定氮法相比,灌注色谱法能够在更短的分析时间内获得总蛋白质含量,同时能够分离出不同种类的蛋白质。由于工业玉米产品的多样性和复杂性,所提出的色谱方法可能是对其常规分析非常有用的工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号