首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >Optimization and validation method to evaluate the residues of beta-lactams and tetracyclines in kidney tissue by UPLC-MS/MS
【24h】

Optimization and validation method to evaluate the residues of beta-lactams and tetracyclines in kidney tissue by UPLC-MS/MS

机译:利用UPLC-MS / MS评价肾脏组织中β-内酰胺和四环素残留的优化和验证方法

获取原文
获取原文并翻译 | 示例
           

摘要

Methods are validated by a process that defines the analytical requirements and confirms that the investigated method is capable of performing consistently. A quantitative and confirmatory method for determining the presence of beta-lactam and tetracycline multiresidues in avian, bovine, equine, and swine kidney tissues using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed, optimized, and validated. Analytes were extracted from the kidneys by a mixture of water and acetonitrile, and the extract was then purified with hexane and C18 (dispersive phase). The method was evaluated by the following parameters: linearity, matrix effect, specificity, decision limits (CC alpha), detection capability (CC beta), accuracy, precision, trueness, limits of detection (LOD), limits of quantification (LOQ), and robustness. The validated method presented a broad linear study range and significant matrix effect. The limit of detection (LOD) was defined from 2.5 to 25.0 mu g kg(-1), and the limit of quantification (LOQ) was defined from 5.0 to 50.0 mu g kg(-1) for individual analytes. The resultant recovery values ranged from 98.1% to 107.3% in repeatability conditions and from 95.2% to 106% under intralaboratory reproducibility conditions for the studied analytes. It was concluded that the performance parameters demonstrated total method adequacy for detecting and quantifying beta-lactam and tetracycline residues in swine, equine, bovine, and avian kidneys. (C) 2015 Elsevier B.V. All rights reserved.
机译:通过定义分析要求并确认所研究方法能够一致执行的过程来验证方法。开发,优化和确定了一种定量和确证的方法,使用超高效液相色谱-串联质谱法(UPLC-MS / MS)测定禽,牛,马和猪肾组织中β-内酰胺和四环素的多残留量。已验证。用水和乙腈的混合物从肾脏中提取分析物,然后用己烷和C18(分散相)纯化提取物。通过以下参数对方法进行了评估:线性,基质效应,特异性,决策限(CC alpha),检测能力(CC beta),准确性,精密度,真实性,检测限(LOD),定量限(LOQ),和鲁棒性。经过验证的方法具有广阔的线性研究范围和显着的基质效应。单个分析物的检测极限(LOD)定义为2.5至25.0μg kg(-1),定量极限(LOQ)定义为5.0至50.0μg kg(-1)。在所研究的分析物的重复性条件下,最终的回收率值在98.1%至107.3%的范围内,而在实验室内的再现性条件下,所得的回收率在95.2%至106%的范围内。结论是,性能参数证明了在猪,马,牛和禽肾中检测和定量β-内酰胺和四环素残留的总体方法充分性。 (C)2015 Elsevier B.V.保留所有权利。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号