首页> 外文期刊>Analytica chimica acta >Sequential injection analysis (SIA)-chemiluminescence determination of indomethacin using tris[(2,2'-bipyridyl)]ruthenium(III) as reagent and its application to semisolid pharmaceutical dosage forms
【24h】

Sequential injection analysis (SIA)-chemiluminescence determination of indomethacin using tris[(2,2'-bipyridyl)]ruthenium(III) as reagent and its application to semisolid pharmaceutical dosage forms

机译:以三[(2,2'-联吡啶基)]钌(III)为试剂的顺序注射分析(SIA)-化学发光法测定吲哚美辛及其在半固体药物剂型中的应用

获取原文
获取原文并翻译 | 示例
       

摘要

Automated sequential injection (SIA) method for chemiluminescence (CL) determination of nonsteroidal anti-inflammatory drug indomethacin (I) was devised. The CL radiation was emitted in the reaction of I (dissolved in aqueous 50% v/v ethanol) with intermediate reagent tris(2,2'-bipyridyl)ruthenium(III) (Ru(bipy)_3~(3+)) in the presence of acetate. The Ru(bipy)_3~(3+) was generated on-line in the SIA system by the oxidation of 0.5 mM tris(2,2'-bipyridyl)ruthenium(II) (Ru(bipy)_3~(2+)) with Ce(IV) ammonium sulphate in diluted sulphuric acid. The optimum sequence, concentrations, and aspirated volumes of reactant zones were: 15 mM Ce(IV) in 50 mM sulphuric acid 41 muL, 0.5 mM Ru(bipy)_3~(2+) 30 mu L, 0.4M Na acetate 16 mu L and I sample 15 mu L; the flow rates were 60 muLs~(-1) for the aspiration into the holding coil and 100 mu L s~(-1) for detection. Calibration curve relating the intensity of CL (peak height of the transient CL signal) to concentration of I was curvilinear (second order polynomial) for 0.1-50 mu M I (r = 0.9997; n = 9) with rectilinear section in the range 0.1-10 mu M I (r = 0.9995; n = 5). The limit of detection (3 sigma) was 0.05 mu M I. Repeatability of peak heights (R.S.D., n = 10) ranged between 2.4% (0.5 mu M I) and 2.0% (7 mu M I). Sample throughput was 180 h~(-1). The method was applied to determination of 1 to 5% of I in semisolid dosage forms (gels and ointments). The results compared well with those of UV spectrophotometric method.
机译:设计了自动序贯注射(SIA)化学发光(CL)测定非甾体抗炎药消炎痛(I)的方法。在I(溶于50%v / v乙醇水溶液)与中间试剂tris(2,2'-bipyridyl)钌(III)(Ru(bipy)_3〜(3+))的反应中发出CL辐射乙酸盐的存在。 Ru(bipy)_3〜(3+)是在SIA系统中通过氧化0.5 mM的tris(2,2'-bipyridyl)钌(II)(Ru(bipy)_3〜(2+) )与硫酸铈(四)铵在稀硫酸中的溶液。反应物区域的最佳顺序,浓度和抽吸体积为:在50 mM硫酸中的15 mM Ce(IV)41μL,0.5 mM Ru(bipy)_3〜(2+)30μL,0.4M乙酸钠16μL我和我取样15亩L;吸入保持线圈的流量为60μLs〜(-1),检测为100μLs〜(-1)。将CL的强度(瞬态CL信号的峰值高度)与I的浓度相关联的校准曲线对于0.1-50μMI(r = 0.9997; n = 9)具有曲线(二阶多项式),直线部分的范围为0.1- 10微米MI(r = 0.9995; n = 5)。检测限(3σ)为0.05μM I.峰高的重复性(R.S.D.,n = 10)在2.4%(0.5μM I)和2.0%(7μM I)之间。样品通量为180 h〜(-1)。该方法用于测定半固体剂型(凝胶和软膏)中1%至5%的I。结果与紫外分光光度法比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号