Between 2002 and 2004, panels of amniotic fluid containing varying concentrations of Toxoplasma gondii were sent to up to 23 laboratories in France for molecular (PCR-based) detection as part of a national quality assurance initiative in the molecular prenatal diagnosis of toxoplasmosis. Participants were free to enroll and no fees were required. The general level of sensitivity was high, and the rate of false-positive reactions was relatively low. Considerable diversity among PCR methods and primers was revealed. This external quality assurance scheme provided the opportunity to improve laboratory practice and performance, and to increase communication among laboratories involved in making this diagnosis.
机译:在2002年至2004年之间,作为国家质量保证计划的一部分,在弓形虫的分子产前诊断中,将含有不同浓度的弓形虫的羊水样本送到法国的23个实验室进行分子检测(基于PCR)。参与者可以免费注册,不需要任何费用。总体敏感性水平较高,假阳性反应率相对较低。揭示了PCR方法和引物之间相当大的多样性。这种外部质量保证计划提供了改善实验室实践和性能,以及增加参与做出此诊断的实验室之间交流的机会。