首页> 外文期刊>Clinical and Experimental Immunology: An Official Journal of the British Society for Immunology >First steps in the standardization of immunoglobulin IgG myeloperoxidase-anti-neutrophil cytoplasmic antibody measurements
【24h】

First steps in the standardization of immunoglobulin IgG myeloperoxidase-anti-neutrophil cytoplasmic antibody measurements

机译:免疫球蛋白IgG髓过氧化物酶抗中性粒细胞胞质抗体标准化的第一步

获取原文
获取原文并翻译 | 示例
       

摘要

The standardization of immunoassays for immunoglobulin (Ig)G myeloperoxidase-anti-neutrophil cytoplasmic antibodies (MPO-ANCA) could contribute to a more accurate diagnosis and follow-up of small vessels-associated vasculitis, a systemic autoimmune disorder that leads to necrosis of blood vessel walls. Despite significant efforts by different groups, the level of comparability of results from commercially available immunoassays used for IgG MPO-ANCA detection is still poor. Therefore, the potential for improvement using reference materials was assessed. The evaluation of a set of 30 patient samples with 11 assays showed that differences between assays result in different interpretations for individual patients. Only 10 of 30 patient samples had the same clinical interpretation among 11 assays applying the cut-off values provided by each respective manufacturer. The correlation between results from 13 different assays was assessed in a pairwise manner. The correlation between results from patient samples was systematically very good for combinations of seven of those assays. The correlation of results ranged from reasonable to good for combinations with four other assays, therefore it should be possible to improve the comparability of results using a commutable reference material for calibration. Feasibility studies were conducted in order to find a reference material format most suitable for a calibrator. Two sets of candidate reference materials were produced from different raw materials, and assessed according to their suitability. A final format was selected, and a candidate reference material was produced.
机译:免疫球蛋白(Ig)G髓过氧化物酶抗中性粒细胞胞浆抗体(MPO-ANCA)免疫测定的标准化可有助于更准确地诊断和随访小血管相关性血管炎,这是一种导致血液坏死的全身性自身免疫性疾病血管壁。尽管不同小组做出了巨大努力,但用于IgG MPO-ANCA检测的市售免疫测定结果的可比性水平仍然很差。因此,评估了使用参考材料改善的潜力。用11种测定法对一组30个患者样品的评估表明,测定法之间的差异导致对各个患者的解释不同。在使用各制造商提供的临界值的11种测定中,30种患者样品中只有10种具有相同的临床解释。以成对方式评估了13种不同测定结果之间的相关性。对于这些测定中的七个测定,患者样品结果之间的系统相关性非常好。对于与其他四种测定法的组合,结果的相关性从合理到良好不等,因此,应该有可能使用可互换的参考材料进行校准来提高结果的可比性。为了找到最适合校准器的参考材料格式,进行了可行性研究。从不同的原材料生产出两组候选参考材料,并根据其适用性进行评估。选择了最终格式,并制作了候选参考材料。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号