The authors to describe the technique and report the results of percutaneous displacement of endoscopically placed plastic biliary endoprostheses into the duodenum at the time of transhepatic intervention in 34 patients. Displacement into the duodenum was effected by simply passing a guide wire through the stent, and then pushing it into the gut with a catheter. Thirty-three of 36 stents (92%) were successfully displaced in this manner. No complications related to stent passage out of the gastrointestinal tract were encountered. Plastic biliary stents can be safely displaced into the duodenum when patients undergo transhepatic biliary procedures, thus avoiding repeated endoscopy.
机译:作者描述了该技术,并报告了经肝内介入治疗时经内镜放置的塑料胆管内假体经皮置换进入十二指肠的结果,共34例患者。只需将导丝穿过支架,然后用导管将其推入肠内,即可将其移入十二指肠。以这种方式成功置换了33个支架中的33个(占92%)。没有遇到与支架从胃肠道传出有关的并发症。当患者进行经肝胆道手术时,可将塑料胆道支架安全地移入十二指肠,从而避免重复内镜检查。