Assessment of total body water and its compartments in elite judo athletes: comparison of bioelectrical impedance spectroscopy with dilution techniques

机译:评估柔道运动员体内总水及其隔室的作用:采用稀释技术的生物电阻抗光谱法的比较

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Bioelectrical impedance spectroscopy (BIS) is an inexpensive and non-invasive technique to measure total body water (TBW), extracellular water (ECW), and intracellular water (ICW). The purpose of this study was to validate TBW, ECW and ICW assessed by BIS, using dilution techniques as the reference method (REF) in elite judo athletes. Thirty-two Portuguese elite male judo athletes were evaluated during a period of weight stability. TBW, ECW and ICW were assessed by BIS (Xitron 4000). Deuterium and bromide dilution techniques were used as the criterion method for measuring TBW and ECW, while ICW was calculated as the difference between the two. BIS explained 96%, 77% and 94% of the total variability from REFs for TBW, ECW and ICW, respectively. BIS also demonstrated high precision (rho >= 0.88) and accuracy (C-b=0.98), with a minimum concordance coefficient correlation of 0.87 for ECW. The mean bias demonstrated that BIS slightly overestimated the REF in 1.1kg (2.3%), 0.3kg (1.6%) and 0.8kg (2.7%) for TBW, ECW and ICW, respectively. The 95% limits of agreement ranged from -1.2 to 3.3kg in TBW, from -1.8 to 2.4kg in ECW and from -1.0 to 2.6kg in ICW. A non-significant trend was found between the difference and the mean of reference and alternative methods. These findings highlight the efficacy of BIS as a valid non-biased tool for the assessment of TBW and its compartments in elite male judo athletes, during a period of weight stability.
机译:生物电阻抗光谱法(BIS)是一种便宜且无创的技术,可用于测量全身水(TBW),细胞外水(ECW)和细胞内水(ICW)。这项研究的目的是通过使用稀释技术作为柔道优秀运动员的参考方法(REF)来验证BIS评估的TBW,ECW和ICW。在体重稳定期间,对32名葡萄牙精英男子柔道运动员进行了评估。 TBW,ECW和ICW由BIS(Xitron 4000)进行评估。氘和溴化物稀释技术用作测量TBW和ECW的标准方法,而ICW计算为两者之间的差异。对于TBW,ECW和ICW,BIS分别解释了REF的总变异性的96%,77%和94%。 BIS还显示出高精度(rho> = 0.88)和准确性(C-b = 0.98),其中ECW的最小一致性系数相关系数为0.87。平均偏差表明,对于TBW,ECW和ICW,BIS分别略微高估了REF:1.1kg(2.3%),0.3kg(1.6%)和0.8kg(2.7%)。协议限制的95%范围在TBW中为-1.2至3.3kg,在ECW中为-1.8至2.4kg,在ICW中为-1.0至2.6kg。在参考方法和替代方法的差异与平均值之间发现了不显着的趋势。这些发现强调了BIS在体重稳定期间,是一种有效的非偏见工具,可用于评估优秀柔道运动员中TBW及其隔室的有效性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号