首页> 外文期刊>Journal of radiological protection: Official journal of the Society for Radiological Protection >The impact of x-ray tube configuration on the eye lens and extremity doses received by cardiologists in electrophysiology room
【24h】

The impact of x-ray tube configuration on the eye lens and extremity doses received by cardiologists in electrophysiology room

机译:X射线管配置对电生理室心脏病医生所接受的眼镜和四肢剂量的影响

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

The aim of the study was to analyse the influence of the x-ray tube configuration on the radiation doses to eye lens and extremities of cardiologists performing pacemaker implantation procedures in electrophysiology laboratory. The measurements were performed on one, widely used, portable C-arm system, first with x-ray tube mounted above the patient table and image intensifier below it and then on a reinstalled (but essentially the same) system with under-table x-ray tube configuration. Thermoluminescent dosimeters, placed in various positions near the eye lens, on the hands and ankle, were used during every procedure. The comparison of doses received by cardiologists after changing the x-ray tube configuration from over-to under-table shows statistically significant dose reduction (p < 0.009) for the eye lens closest to the x-ray tube, left finger, left wrist, while for the ankle a dose increase is observed. The corresponding over-to under-table x-ray tube median dose ratios are 4.1 for the right eye, 4.8 for the left finger, 3.0 for left wrist and, finally, 0.13 for the right ankle. Systems with under-table x-ray tube are preferable from a radiation protection point of view. The observed significant increase in doses to the legs should be partially compensated by the use of a protective lead curtain.
机译:这项研究的目的是分析X射线管配置对放射电镜对心脏电生理实验室中进行起搏器植入程序的眼科医生和四肢的辐射剂量的影响。测量是在一个广泛使用的便携式C型臂系统上进行的,首先在患者床上方安装X射线管,在其下方安装图像增强器,然后在重新安装(但基本相同)的系统下使用X射线照相台进行测量。射线管配置。在每个过程中,都使用热发光剂量计,该剂量计放置在眼镜附近,手和脚踝的各个位置。比较心脏病专家在将X射线管配置从桌子上方更改为桌子下方后所收到的剂量,从统计学角度来看,最接近X射线管,左手指,左手腕,而脚踝的剂量增加。相应的从桌下到下层的X射线管中值剂量比是:右眼为4.1,左手为4.8,左手腕为3.0,右脚踝最终为0.13。从辐射防护的角度来看,带有台面X射线管的系统是优选的。观察到的腿部剂量的显着增加应该通过使用铅防护帘来部分补偿。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号