首页> 外文期刊>Journal of liquid chromatography and related technologies >Parallel factor analysis and trilinear partial least squares applied to the UPLC-PDA data array for the quantification of brimonidine tartrate and timolol maleate in an eye drop formulation
【24h】

Parallel factor analysis and trilinear partial least squares applied to the UPLC-PDA data array for the quantification of brimonidine tartrate and timolol maleate in an eye drop formulation

机译:平行因子分析和三线性偏最小二乘应用于UPLC-PDA数据阵列以定量滴眼剂中酒石酸溴莫尼定和马来酸替莫洛尔的含量

获取原文
获取原文并翻译 | 示例
           

摘要

Simultaneous quantification of brimonidine tartrate (BRI) and timolol maleate (TIM) in an eye drop formulation was performed by applying parallel factor analysis (PARAFAC) and trilinear (three way) partial least squares to the ultra performance liquid chromatography-photodiode array (UPLC-PDA) data array. In PARAFAC and 3 W-PLS1 applications, the co-elution of the related compounds in their chromatograms obtained in the presence of ornidazole as an internal standard (IS) was resolved, and then analyses were performed. On the other hand, a new conventional ultra performance liquid chromatography (UPLC) method was developed after long and tedious studies to get desirable elution of BRI and TIM in a chromatogram using different column and mobile phase system than that of chromatographic conditions of PARAFAC and 3 W-PLS1 applications. The performance and validity of all the proposed methods were confirmed by analyzing independent validation samples consisting of synthetic mixture, intraday and interday samples, and standard addition samples. Analysis results of BRI and TIM in eye drop samples by chemometric PARAFAC and 3 W-PLS1, and conventional UPLC were statistically compared to each other. It was concluded that PARAFAC and 3 W-PLS1 have shortest analysis time and lower cost than the developed conventional UPLC method for the analysis of the related compounds in commercial eye drop preparation with adequate selectivity and sensitivity.
机译:滴眼剂中酒石酸溴莫尼定(BRI)和马来酸替莫洛尔(TIM)的同时定量是通过将平行因子分析(PARAFAC)和三线性(三向)偏最小二乘应用于超高效液相色谱-光电二极管阵列(UPLC- PDA)数据阵列。在PARAFAC和3 W-PLS1应用中,解决了相关化合物在奥硝唑作为内标(IS)存在下色谱图中的共洗脱问题,然后进行了分析。另一方面,经过长期而繁琐的研究,开发了一种新的常规超高效液相色谱(UPLC)方法,以使用与PARAFAC和3色谱条件不同的色谱柱和流动相系统,在色谱图中获得理想的BRI和TIM洗脱。 W-PLS1应用程序。通过分析由合成混合物,日间和日间样品以及标准加成样品组成的独立验证样品,可以验证所有建议方法的性能和有效性。将化学计量学PARAFAC和3 W-PLS1与常规UPLC在滴眼液样品中BRI和TIM的分析结果进行统计学比较。得出的结论是,PARAFAC和3 W-PLS1的分析时间最短,成本也低于开发的常规UPLC方法,该方法可对商业滴眼剂中的相关化合物进行分析,具有足够的选择性和灵敏度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号