首页> 外文期刊>Journal of pediatric orthopaedics >Qualitative Versus Quantitative Radiographic Analysis of Foot Deformities in Children With Hemiplegic Cerebral Palsy.
【24h】

Qualitative Versus Quantitative Radiographic Analysis of Foot Deformities in Children With Hemiplegic Cerebral Palsy.

机译:偏瘫性脑瘫患儿足部畸形的定性与定量放射学分析。

获取原文
获取原文并翻译 | 示例

摘要

BACKGROUND:: Qualitative assessments of standing plain radiographs are frequently used to determine treatment strategies and assess outcomes for the management of a wide range of foot and ankle conditions in children. A quantitative technique for such analyses would presumably be more precise and reliable. The goal of this study was to compare qualitative and quantitative techniques for the assessment of plain radiographs of the foot and ankle in children with hemiplegic type cerebral palsy (CP). METHODS:: Standing anteroposterior and lateral radiographs of the foot and ankle of the involved side for 49 children with hemiplegic CP were analyzed qualitatively by 2 pediatric orthopaedists, based upon a 3-segment (hindfoot, midfoot, and forefoot) foot model. Quantitative assessment of the same radiographs was performed by 2 examiners, using 6 radiographic measurements developed to describe the alignment of the foot based upon the same 3-segment model. Intraobserver and interobserver reliability was determined for both the qualitative and the quantitative techniques. The qualitative and quantitative techniques were compared to determine agreement. RESULTS:: The qualitative technique demonstrated poor-to-fair interobserver reliability (percent agreement range, 23%-31%; weighted kappa range, 0.291-0.568). The quantitative technique demonstrated good-to-excellent intraobserver (correlation coefficient range, 0.81-0.99) and interobserver (correlation coefficient range, 0.81-0.97) reliability. Percent agreement between the quantitative and the qualitative techniques for the assessment of foot segmental alignment for each examiner ranged from 22.2% to 100% (mean agreement for examiner 1 was 51% [correlation coefficient range, 0.04-0.48]; mean agreement for examiner 2 was 65.3% [correlation coefficient range, 0.22-0.85]). Percent agreement between the quantitative technique and both observers ranged from 11.1% to 83.3% (mean agreement was 36.7% [correlation coefficient range, 0.17-0.94]). DISCUSSION:: Reliable quantitative radiographic analysis of the segmental alignment of the involved foot and ankle in children with hemiplegic CP is possible and is more precise and reliable than traditional qualitative techniques. Quantitative techniques can identify a wider range of foot segmental malalignments and should facilitate deformity analysis, preoperative planning, assessment of outcome, and comparison of results between centers.
机译:背景:站立平片的定性评估通常用于确定治疗策略和评估结果,以管理儿童的各种足部和踝部疾病。这种分析的定量技术可能更精确,更可靠。这项研究的目的是比较定性和定量技术,以评估偏瘫型脑性瘫痪(CP)儿童的脚和脚踝X线平片。方法:根据3段(后足,中足和前足)足部模型,由2名儿科矫形师定性分析了49名偏瘫CP儿童患侧脚和踝的前后前后X线照片。 2名检查者对同一张X射线照片进行了定量评估,并使用6个X射线照片进行了测量,以描述基于相同的3段模型的脚的对齐方式。在定性和定量技术上都确定了观察者间和观察者间的可靠性。比较定性和定量技术以确定一致性。结果::定性技术显示观察者之间的公平性不佳(一致性百分比范围为23%-31%;加权kappa范围为0.291-0.568)。定量技术表明观察者内(相关系数范围为0.81-0.99)和观察者间(相关系数范围为0.81-0.97)具有良好的可靠性。评估每个检查者的脚部节段对准程度的定量和定性技术之间的一致性百分比在22.2%至100%之间(对检验者1的平均一致性为51%[相关系数范围,0.04-0.48];对于检验者2的平均一致性为65.3%[相关系数范围,0.22-0.85]。定量技术与两位观察者之间的一致性百分比在11.1%到83.3%之间(平均一致性为36.7%[相关系数范围,0.17-0.94])。讨论::偏瘫性CP患儿脚和踝部节段排列的可靠定量放射照相分析是可能的,并且比传统的定性技术更精确,更可靠。定量技术可以识别范围更大的足节节错,并应有助于畸形分析,术前计划,结果评估以及中心之间结果的比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号