...
首页> 外文期刊>Clinical rehabilitation >Reproducibility, validity and responsiveness of the 200-metre fast walk test in patients undergoing cardiac rehabilitation
【24h】

Reproducibility, validity and responsiveness of the 200-metre fast walk test in patients undergoing cardiac rehabilitation

机译:心脏康复患者200米快速步测的重现性,有效性和响应性

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Objective: To investigate the reliability, validity and responsiveness of the 200-metre fast walk test in patients with coronary artery disease engaged in a cardiac rehabilitation programme. Design: Descriptive study. Setting: Tertiary care hospital. Subjects: Thirty stable patients with coronary artery disease (51.9 ± 8.7 years), referred to the cardiac rehabilitation department after an acute coronary syndrome. Intervention: Not applicable. Main measures: Six-minute walk test distance, time to perform the 200-m fast walk test, peak power output of the graded maximal exercise test, before and after the programme; SF-36 quality of life questionnaire at baseline. Walk tests were performed twice at baseline to assess reliability. Results: The 200-m fast walk test was highly reliable (ICC = 0.97). It was significantly correlated with the graded maximal exercise test peak power and the 6-minute walk test at baseline (r = -0.417; P < 0.05; and r = -0.566; P < 0.01, respectively) and after the training programme (r = -0.460, P < 0.05; and r = -0.926; P < 0.01, respectively). At baseline, there was a strong correlation between the 200-m fast walk test time and the physical component score of the SF-36 (r = -0.77; P < 0.01), but not between the 200-m fast walk test time and the SF-36 mental component score. Mean 200-m fast walk test time was significantly different between the patients performing ≤90 W (n = 11) or ≥100 W (n = 19) at the baseline graded maximal exercise test (121.7 ± 13.6 vs. 115.5 ± 10.1 seconds; P < 0.05). The responsiveness was strong with a standardized response mean at 1.11.
机译:目的:探讨参与心脏康复计划的冠心病患者200米快速行走测试的可靠性,有效性和反应性。设计:描述性研究。单位:三级医院。受试者:30名稳定的冠状动脉疾病患者(51.9±8.7岁),在急性冠状动脉综合征后转诊至心脏康复科。干预:不适用。主要措施:六分钟步行测试距离,执行程序200m快速步行测试的时间,程序前后的分级最大运动测试的峰值功率输出;基线时的SF-36生活质量调查表。在基线进行了两次步行测试以评估可靠性。结果:200米快速行走测试非常可靠(ICC = 0.97)。它与分级最大运动测试峰值功率和基线时的6分钟步行测试显着相关(r = -0.417; P <0.05;和r = -0.566; P <0.01)和训练计划后(r = -0.460,P <0.05;和r = -0.926; P <0.01)。在基线时,200 m的快速步行测试时间与SF-36的物理成分评分之间存在很强的相关性(r = -0.77; P <0.01),而200 m的快速步行测试时间与SF-36精神成分评分。在基线分级最大运动测试中,执行≤90W(n = 11)或≥100W(n = 19)的患者,平均200 m快速行走测试时间显着不同(121.7±13.6 vs. 115.5±10.1秒; P <0.05)。响应能力强,标准化响应平均值为1.11。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号