首页> 外文期刊>Chemical Engineering Communications >Construction and Performance Characteristics of Modified Screen Printed and Modified Carbon Paste Sensors for Selective Determination of Cu(II) Ion in Different Polluted Water Samples
【24h】

Construction and Performance Characteristics of Modified Screen Printed and Modified Carbon Paste Sensors for Selective Determination of Cu(II) Ion in Different Polluted Water Samples

机译:选择性筛选测定不同污染水样中铜离子的改进型丝网印刷和碳糊传感器的构造和性能特征

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Four new ion-selective electrodes (ISEs), based on N,N-bis(salicylaldehyde)-p-phenylene diamine (SPD) as ionophore, are constructed for the determination of copper(II) ion. The modified carbon paste (MCPEs; electrodes I and II) and modified screen-printed sensors (MSPEs; electrodes III and IV) exhibit good potentiometric response for Cu(II) over a wide concentration range of 1.0x10(-6)-1.0x10(-2)molL(-1) for electrodes (I and II) and 4.8x10(-7)-1.0x10(-2)molL(-1) for electrodes (III and IV) with a detection limit of 1.0x10(-6)molL(-1) for electrodes (I and II) and 4.8x10(-7)molL(-1) for electrodes (III and IV), respectively. The slopes of the calibration graphs are 29.62 +/- 0.9 and 30.12 +/- 0.7mV decade(-1) for electrode (I) (tricresylphosphate (TCP) plasticizer) and electrode (II) (o-nitrophenyloctylether o-NPOE plasticizer), respectively. Also, the MSPEs showed good potentiometric slopes of 29.91 +/- 0.5 and 30.70 +/- 0.3mV decade(-1) for electrode (III) (TCP plasticizer) and electrode (IV) (o-NPOE plasticizer), respectively. The electrodes showed stable and reproducible potentials over a period of 60, 88, 120, and 145 days at the pH range from 3 to 7 for electrodes (II), (III), and (IV) and pH range from 3 to 6 for electrode (I). This method was successfully applied for potentiometric determination of Cu(II) in tap water, river, and formation water samples in addition to pharmaceutical preparation. The results obtained agree with those obtained with the atomic absorption spectrometry (AAS).
机译:基于N,N-双(水杨醛)-对亚苯基二胺(SPD)作为离子载体构建了四个新的离子选择电极(ISEs),用于测定铜(II)离子。改性碳糊(MCPE;电极I和II)和改性丝网印刷传感器(MSPE;电极III和IV)在1.0x10(-6)-1.0x10的宽浓度范围内对Cu(II)表现出良好的电位响应电极(I和II)的(-2)molL(-1)和电极(III和IV)的4.8x10(-7)-1.0x10(-2)molL(-1),检测限为1.0x10(电极(I和II)的-6)molL(-1)和电极(III和IV)的4.8x10(-7)molL(-1)。电极(I)(磷酸三甲苯酯(TCP)增塑剂)和电极(II)(邻硝基苯基辛基醚o-NPOE增塑剂)的校准曲线图的斜率分别为29.62 +/- 0.9和30.12 +/- 0.7mV十进位(-1) , 分别。同样,对于电极(III)(TCP增塑剂)和电极(IV)(o-NPOE增塑剂),MSPEs分别显示出29.91 +/- 0.5和30.70 +/- 0.3mV十倍数(-1)的良好电位差。在电极(II),(III)和(IV)的pH范围为3至7的情况下,电极在60、88、120和145天内显示出稳定且可重现的电位,对于电极(II),(IV)的pH范围为3至6。电极(I)。该方法已成功用于自来水,河流和地层水样品中的铜(II)电位测定,以及药物制备。获得的结果与通过原子吸收光谱法(AAS)获得的结果一致。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号