首页> 美国卫生研究院文献>Journal of Pharmaceutical Analysis >In situ modified screen printed and carbon paste ion selective electrodes for potentiometric determination of naphazoline hydrochloride in its formulation
【2h】

In situ modified screen printed and carbon paste ion selective electrodes for potentiometric determination of naphazoline hydrochloride in its formulation

机译:原位修饰丝网印刷和碳糊离子选择电极用于电位测定萘甲唑啉

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The construction and performance characteristics of new sensitive and selective in situ modified screen printed (ISPE) and carbon paste (ICPE) electrodes for determination of naphazoline hydrochloride (NPZ-HCl) have been developed. The electrodes under investigation show potentiometric response for NPZ-HCl in the concentration range from 7.0×10–7 to 1.0×10–2 M at 25 °C and the electrode response is independent of pH in the range of 3.1–7.9. These sensors have slope values of 59.7±0.6 and 59.2±0.2 mV decade−1 with detection limit values of 5.6×10–7 and 5.9×10–7 M NPZ-HCl using ISPE and ICPE, respectively. These electrodes show fast response time of 4–7 s and 5–8 s and exhibits lifetimes of 28 and 30 days for ISPE and ICPE, respectively. Selectivity for NPZ-HCl with respect to a number of interfering materials was also investigated. It was found that there is no interference from the investigated inorganic cations, anions, sugars and other pharmaceutical excipients. The proposed sensors were applied for the determination of NPZ-HCl in pharmaceutical formulation using the direct potentiometric method. It showed a mean average recovery of 100.2% and 102.6% for ISPE and ICPE, respectively. The obtained results using the proposed sensors were in good agreement with those obtained using the official method. The proposed sensors show significantly high selectivity, response time, accuracy, precision, limit of detection (LOD) and limit of quantification (LOQ) compared with other proposed methods.
机译:已开发出用于测定盐酸萘甲唑啉(NPZ-HCl)的新型敏感和选择性原位修饰丝网印刷(ISPE)和碳糊(ICPE)电极的结构和性能特征。所研究的电极在25°C下显示浓度范围为7.0×10 –7 至1.0×10 –2 M时NPZ-HCl的电位响应和电极响应在3.1-7.9范围内与pH无关。这些传感器的斜率值为59.7±0.6和59.2±0.2 mV decade −1 ,检测极限值为5.6×10 –7 和5.9×10 –7 分别使用ISPE和ICPE的M NPZ-HCl。这些电极的快速响应时间为4-7秒和5-8秒,对于ISPE和ICPE分别具有28天和30天的寿命。还研究了NPZ-HCl对多种干扰物质的选择性。发现所研究的无机阳离子,阴离子,糖和其他药物赋形剂没有干扰。所提出的传感器用于直接电位法测定药物制剂中的NPZ-HCl。 ISPE和ICPE的平均平均回收率分别为100.2%和102.6%。使用建议的传感器获得的结果与使用官方方法获得的结果非常一致。与其他拟议方法相比,拟议中的传感器显示出很高的选择性,响应时间,准确性,精度,检测限(LOD)和定量限(LOQ)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号