Assessing the influence of antivibration glove on digital vascular responses to acute hand-arm vibration.

机译:评估防振手套对数字血管对急性手臂振动的反应的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

This study was designed to assess the influence of an antivibration glove on digital vascular responses in healthy subjects exposed to short-term grasping of a vibrating handle. To measure finger blood flow (FBF) and finger skin temperature (FST) once at the end of every min, a blood flowmeter sensor was attached to the dorsum and a thermistor sensor was attached to the medial surface of the subject's middle phalanx of the third finger of the right hand. After 5 min of baseline measurements without or with an antivibration glove meeting ISO standard 10819, worn on the right hand, subjects gripped a vibrating handle with the same hand for a period of 5 min. Vibration was generated at two frequencies of 31.5 Hz and 250 Hz with a frequency weighted rms acceleration of 5.5 m/s(2). FBF and FST continued to be recorded for a further 5 min after release of the vibrating handle. Statistical analysis showed no significant change after vibration exposure in either FST or FBF at 250 Hz, compared to baseline (control) measurements while using the antivibration glove. At 31.5 Hz, FBF data exhibited a significant difference between before and after grasping of vibrating handle, which was less under the condition of wearing the antivibration glove than under the condition of bare hand. The results provide evidence that the antivibration glove considerably influenced finger vascular changes in healthy subjects induced by vibration exposure, especially against high frequency vibration. Further studies are required to assess finger vascular responses to hand-transmitted vibration with antivibration gloves of different manufacturers.
机译:这项研究旨在评估在短期握住振动手柄的健康受试者中,防振手套对数字血管反应的影响。为了在每分钟结束时一次测量手指血流量(FBF)和手指皮肤温度(FST),将血液流量计传感器连接到背部,热敏电阻传感器连接到受试者的第三趾中指骨的内侧表面右手的手指。基线测量5分钟后,右手戴或不戴符合ISO标准10819的防振手套,受试者用同一只手握住振动手柄5分钟。以31.5 Hz和250 Hz的两个频率产生振动,频率加权均方根加速度为5.5 m / s(2)。释放振动手柄后,又连续记录了5分钟的FBF和FST。统计分析表明,与使用防振手套时的基线(对照)测量值相比,在FST或FBF在250 Hz振动暴露后,无明显变化。在31.5 Hz时,握持振动手柄前后的FBF数据显示出显着差异,戴防振手套的情况下FBF数据要比裸手的情况下小。结果提供了证据,该抗振手套显着影响了健康受试者因暴露于振动而产生的手指血管变化,尤其是对抗高频振动。需要使用不同制造商的防震手套进行进一步研究,以评估手指血管对手传递振动的反应。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号