首页> 外文期刊>Journal of Sound and Vibration >A method for assessing the effectiveness of anti-vibration gloves using biodynamic responses of the hand-arm system
【24h】

A method for assessing the effectiveness of anti-vibration gloves using biodynamic responses of the hand-arm system

机译:一种利用手臂系统的生物动力学响应评估防振手套有效性的方法

获取原文
获取原文并翻译 | 示例
           

摘要

Anti-vibration gloves are widely used to help minimize hand-arm vibration exposure. In this study, an alternative method is proposed to assess the vibration isolation effectiveness of these gloves using the biodynamic responses of the bare- and gloved-hand-arm system exposed to vibration. The laboratory experiments were performed with a total of five human subjects using a typical anti-vibration air bladder glove subjected to a broad-band random vibration spectrum in conjunction with a specially designed instrumented handle. The measured data were analyzed to derive the biodynamic responses of the bare as well as gloved human hand-arm system in terms of the apparent mass and the mechanical impedance. The two biodynamic responses were applied to estimate the vibration isolation effectiveness of the glove. The validity of the proposed concept was examined by comparing the estimated vibration transmissibility magnitudes of the glove with those obtained using a palm adapter method. The comparison of the results suggests that the proposed method offers a good alternative for estimating glove vibration transmissibility. The measured data and the proposed method based upon the biodynamic responses were further used to investigate the effect of the palm adapter on the vibration transmissibility of the glove. The results suggest that the presence of the palm adapter between the subject's palm and the glove may not alter the basic trends in the transmissibility response, but it would affect the transmissibility magnitudes in the middle- and high-frequency ranges. A distinct advantage of the proposed method is that it eliminates the use of an adapter in assessing the vibration isolation effectiveness of the gloves. (c) 2004 Elsevier Ltd. All rights reserved.
机译:防振手套被广泛用于帮助最大程度地减少手臂振动的暴露。在这项研究中,提出了一种替代方法,该方法利用暴露于振动的裸手和手套手系统的生物动力响应来评估这些手套的隔振效果。使用典型的防振气囊手套,通过宽带随机振动谱结合专门设计的仪器手柄,对总共五名受试者进行了实验室实验。根据实测质量和机械阻抗,对测量数据进行分析以得出裸露的以及戴手套的人的手臂系统的生物动力响应。应用这两个生物动力响应来估计手套的隔振效果。通过比较估计的手套振动传递幅度与使用手掌适配器方法获得的传递振动幅度,检验了所提出概念的有效性。结果的比较表明,所提出的方法为估计手套振动的传递性提供了一个很好的选择。进一步使用测量数据和基于生物动力学响应的建议方法来研究手掌适配器对手套振动传递性的影响。结果表明,在对象的手掌和手套之间存在手掌适配器可能不会改变透射率响应的基本趋势,但会影响中高频范围内的透射率幅度。所提出的方法的显着优点是,在评估手套的隔振效果时无需使用适配器。 (c)2004 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号