A method for positioning electrodes during surface EMG recordings in lower limb muscles.

机译:一种在下肢肌肉的表面肌电图记录过程中定位电极的方法。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: The aim of this work is to provide information about the degree of inter-subject uniformity of location of innervation zone (IZ) in 13 superficial muscles of the lower limb. The availability of such information will allow researchers to standardize and optimize their electrode positioning procedure and to obtain accurate and repeatable estimates of surface electromyography (sEMG) signal amplitude, spectral variables and muscle fiber conduction velocity. METHODS: Surface EMG signals from gluteus maximus, gluteus medius, tensor faciae latae, biceps femoris, semitendinosus, vastus medialis obliquus, vastus lateralis, rectus femoris, tibialis anterior, peroneus longus, soleus, gastrocnemius medialis and lateralis muscles of ten healthy male subjects aged between 25 and 34 years (average = 29.2 years, S.D. = 2.5 years) were recorded to assess individual IZ location and signal quality. RESULTS: Tensor faciae latae, biceps femoris, semitendinosus, vastus lateralis, gastrocnemius medialis and lateralis showed a high level of both signal quality and IZ location uniformity. In contrast, rectus femoris, gluteus medius and peroneus longus were found to show poor results for both indexes. Gluteus maximus, vastus medialis obliquus and tibialis anterior were found to show high signal quality but low IZ location uniformity. Finally, soleus muscle was found to show low signal quality but high IZ location uniformity. CONCLUSIONS: This study identifies optimal electrode sites for muscles in the lower extremity by providing a standard landmarking technique for the localization of the IZ of each muscle so that surface EMG electrodes can be properly positioned between the IZ and a tendon.
机译:目的:这项工作的目的是提供有关下肢13个浅表肌肉中神经支配区(IZ)位置的受试者间均匀度的信息。这些信息的可用性将使研究人员能够标准化和优化其电极定位程序,并获得对表面肌电图(sEMG)信号幅度,频谱变量和肌纤维传导速度的准确且可重复的估计。方法:表面肌电信号来自臀大肌,臀中肌,张肌筋膜,股二头肌,半腱肌,股内侧斜肌,股外侧肌,股直肌,胫骨前肌,腓骨长肌,比目鱼肌,腓肠肌,内侧腓肠肌和老年肌外侧肌记录25至34年(平均= 29.2年,SD = 2.5年)以评估单个IZ位置和信号质量。结果:张肌筋膜,股二头肌,半腱肌,股外侧肌,腓肠肌内侧肌和外侧肌均表现出高水平的信号质量和IZ位置均匀性。相反,发现股直肌,臀中臀肌和腓骨长直肌两个指标的结果均较差。发现臀大肌,斜肌内侧肌和胫骨前肌显示高信号质量,但IZ位置均匀性低。最后,发现比目鱼肌显示出低信号质量但IZ位置均匀性高。结论:这项研究通过为每条肌肉的IZ定位提供一种标准的标志性技术,从而可以将EMG表面的电极正确地定位在IZ和肌腱之间,从而确定了下肢肌肉的最佳电极位置。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号