Objectives: The aim of this study was to objectively assess the reliability of the cone-beam computed tomography (CBCT) as a tool to pre-operatively determine radiographic bone density (RBD) by the density values provided by the system, analyzing its relationship with histomorphometric bone density expressed as bone volumetric fraction (BV/TV) assessed by micro-CT of bone biopsies at the site of insertion of dental implants in the maxillary bones. Material and methods: Thirty-nine bone biopsies of the maxillary bones at the sites of 39 dental implants from 31 edentulous healthy patients were analyzed. The NobelGuide? software was used for implant planning, which also allowed fabrication of individual stereolithographic surgical guides. The analysis of CBCT images allowed pre-operative determination of mean density values of implant recipient sites along the major axis of the planned implants (axial RBD). Stereolithographic surgical guides were used to guide implant insertion and also to extract cylindrical bone biopsies from the core of the exact implant site. Further analysis of several osseous micro-structural variables including BV/TV was performed by micro-CT of the extracted bone biopsies. Results: Mean axial RBD was 478 ± 212 (range: 144-953). A statistically significant difference (P = 0.02) was observed among density values of the cortical bone of the upper maxilla and mandible. A high positive Pearson's correlation coefficient (r = 0.858, P < 0.001) was observed between RBD and BV/TV, with the regression equations: (1) Axial RBD = -19.974 + 10.238·BV/TV; (2) BV/TV = 14.258 + 0.72·Axial RBD. RBD was also positively correlated with the trabecular thickness (Tb.Th) and trabecular number (Tb.N), but negatively correlated with trabecular separation (Tb.Sp), structural model index, and inverse connectivity (Tb.Pf). Density values upper than 450 were associated with BV/TV upper than 50%, mean Tb.Th upper than 0.2 mm, mean Tb.Sp lower than 0.3 mm, and mean Tb.N upper than 2. Conclusion: RBD assessed by CBCT has a strong positive correlation with BV/TV assessed by micro-CT at the site of dental implants in the maxillary bones. Pre-operative estimation of density values by CBCT is a reliable tool to objectively determine bone density.
机译:目的:本研究的目的是客观评估锥束计算机断层扫描(CBCT)的可靠性,该工具可通过系统提供的密度值在术前确定放射照相的骨密度(RBD),并分析其与骨密度的关系。组织形态计量学的骨密度表示为通过在上颌骨中植入牙种植体的部位的活检组织的显微CT评估的骨体积分数(BV / TV)。材料和方法:分析了来自31名无牙的健康患者的39颗牙种植体部位的上颌骨的39例活检。诺贝尔指南?该软件用于植入物规划,还允许制作单独的立体光刻手术指南。 CBCT图像的分析允许在术前确定沿计划种植体主轴(轴向RBD)的种植体接受部位的平均密度值。立体光刻外科手术指南用于引导植入物的插入,并从确切的植入物部位的核心中提取圆柱状骨活检标本。通过显微CT对提取的骨活检组织进行了包括BV / TV在内的几种骨微结构变量的进一步分析。结果:平均轴向RBD为478±212(范围:144-953)。在上颌骨和下颌骨的皮质骨密度值之间观察到统计学上的显着差异(P = 0.02)。在RBD和BV / TV之间观察到较高的Pearson正相关系数(r = 0.858,P <0.001),回归方程如下:(1)轴向RBD = -19.974 + 10.238·BV / TV; (2)BV / TV = 14.258 + 0.72·轴向RBD。 RBD与骨小梁厚度(Tb.Th)和骨小梁数目(Tb.N)也呈正相关,但与骨小梁间距(Tb.Sp),结构模型指数和反向连接性(Tb.Pf)呈负相关。高于450的密度值与BV / TV高于50%,平均Tb.Th高于0.2 mm,平均Tb.Sp低于0.3 mm,平均Tb.N高于2相关。结论:CBCT评估的RBD具有微型CT在上颌骨种植牙部位与BV / TV呈强正相关。术前通过CBCT估算密度值是客观确定骨密度的可靠工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号