An intercomparison of visual diffuse transmission density measurements of photographic and x-ray film step tablets was completed by two national metrology institutes, the National Institute of Standards and Technology, USA, and the Physikalisch-Technische Bundesanstalt, Germany. The samples were measured by three reference densitometers according to procedures described in international documentary standards. The instruments are well characterized with estimates of their measurement uncertainties. The systematic differences between the density measurements were less than 0.010 for the photographic films and 0.015 for the x-ray films for densities as great as 3.3. [References: 8]
机译:两个国家计量机构,即美国国家标准技术研究院和德国物理技术研究院完成了照相和X射线胶片台阶片的视觉漫透射密度测量的比较。根据国际文献标准中所述的程序,通过三个参考光密度计测量样品。这些仪器通过测量不确定度的估算可以很好地表征。对于照相胶片,密度测量之间的系统差异小于0.010,对于X射线胶片,密度测量之间的系统差异小于0.015,而密度高达3.3。 [参考:8]