...
首页> 外文期刊>Journal of Hand Surgery. American Volume >Comparison of 4 fluoroscopic views for dorsal cortex screw penetration after volar plating of the distal radius
【24h】

Comparison of 4 fluoroscopic views for dorsal cortex screw penetration after volar plating of the distal radius

机译:远端vol骨钢板镀覆后4个透视图对背皮质螺钉穿透的比较

获取原文
获取原文并翻译 | 示例

摘要

Purpose: To determine whether use of the dorsal tangential view improves the diagnostic accuracy of intraoperative fluoroscopy compared with conventional views in detecting dorsal screw penetrations during volar distal radius plating. Methods: Dorsal cortices of 10 cadaveric distal radii were penetrated in each of the second, third, and fourth dorsal extensor compartments at 0, 1, 2, and 3 mm penetration. We obtained 4 standardized fluoroscopic images of the wrist: lateral, supination, pronation, and dorsal tangential views. Using high-definition digital images, 2 observers blinded to the experimental paradigm determined whether screws were penetrating the dorsal cortex. Results: For screws that penetrated the floor of the second dorsal compartment, the 45°supination view was 92% sensitive for detecting screw penetration of 2 mm, and 98% for 3 mm. For screws that penetrated the third dorsal compartment, the lateral view was 68% and 80% sensitive in detecting screw penetrations of 1 and 2 mm, respectively. However, the dorsal tangential view showed 95% sensitivity for 1 mm and 98% for 2 mm penetrations. On the floor of the fourth dorsal compartment, pronation and dorsal tangential views were both 88% sensitive for 1 mm screw penetration and 90% and 93% for 2 mm, respectively. Conclusions: The standard lateral view of the wrist failed to detect all screw penetrations. The dorsal tangential view increased the accuracy of detecting screw penetrations on the floor of the third dorsal compartment, whereas we needed oblique views to detect screw penetrations on the floors of second and fourth dorsal compartments. Clinical relevance: Routine clinical use of the dorsal tangential view has the potential to increase accuracy in detecting dorsal screw penetration during volar plating of the distal radius.
机译:目的:确定使用背切线视图与常规视图相比,在掌侧vol骨远端plating骨穿入过程中检测背螺钉穿透性是否比常规视图提高了术中透视的诊断准确性。方法:在每个第二,第三和第四背侧伸肌室分别以0、1、2和3 mm的穿透深度刺入10个尸体远端半径的背侧皮质。我们获得了手腕的4张标准透视图像:侧面,旋后,前旋和背切线视图。使用高清数字图像,两名对实验范式视而不见的观察者确定了螺钉是否穿透了背皮质。结果:对于穿透第二个背侧室底部的螺钉,45°仰角视图对于检测2 mm的螺钉穿透敏感度为92%,对于3 mm的螺钉穿透敏感度为98%。对于穿透第三个背侧隔室的螺钉,侧视图在检测1毫米和2毫米的螺钉穿透率方面分别为68%和80%。但是,背面切向视图显示1 mm的穿透率为95%,2mm穿透的穿透率为98%。在第四个背侧隔室的地板上,旋入和背切向视图对于1 mm的螺钉穿透分别为88%敏感,对于2 mm的敏感度分别为90%和93%。结论:手腕的标准侧视图无法检测所有螺钉穿透。背切线视图提高了在第三背侧隔室的地板上检测螺钉穿透的准确性,而我们需要倾斜视图以检测第二背侧和第四背侧隔室的地板螺钉穿透。临床意义:常规的背切面临床使用可能会增加在vol骨远端掌侧钢板穿入过程中检测背螺钉穿透的准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号