首页> 外文期刊>Journal of Endodontics: Official Journal of American Association of Endodontists >Effect of EDTA Preparations on Rotary Root Canal Instrumentation
【24h】

Effect of EDTA Preparations on Rotary Root Canal Instrumentation

机译:EDTA制剂对旋转根管器械的影响

获取原文
获取原文并翻译 | 示例
       

摘要

Introduction: The aim of this study was to evaluate whether rotary instrumentation using saline, EDTA 17% solution, or RC-Prep (Premier Dental, Philadelphia, PA) resulted in differences in root canal transportation. The secondary objective was to assess if instrumentation using these agents caused changes in the working length and canal volume. Methods: Moderately curved mesiobuccal roots of 24 maxillary molars were standardized in length and randomized into 1 control and 2 experimental groups. The canals were instrumented with 0.04 taper rotary files to size #30. All groups were irrigated with saline. Group 1 was also irrigated using EDTA 17% solution (Pulpdent Corp, Watertown, MA), and in group 2, RC-Prep was used.. X-ray micro computed tomographic scans and working length measurements were made before and after instrumentation. Three-dimensional models were created from the pre- and postinstrumentation scan data and compared for volume changes. Centroid points were calculated in cross-sectional slices of the canals, and transportation was determined by measuring the distance between the pre- and postinstrumentation points. The data were analyzed with 1-way analysis of variance (alpha = 0.05) and the Tukey post hoc test. Results: Less transportation was observed in group 2 than in group 1 (P = .001) and the control group (P = .014). Transportation in group 1 and the control group was not significantly different. Canal volume in group 1 was increased relative to group 2 (P = .004) and the control group (P = .022). No significant differences in the working length were observed. Conclusions: The use of chelating agents during root canal instrumentation did not significantly increase apical transportation.
机译:简介:这项研究的目的是评估使用盐水,EDTA 17%溶液或RC-Prep(宾夕法尼亚州费城,Premier Dental)的旋转器械是否导致根管运输的差异。第二个目的是评估使用这些药物的器械是否引起工作长度和根管容积的变化。方法:对24个上颌磨牙的中度弯曲的近颊根进行长度标准化,并随机分为1个对照组和2个实验组。用0.04锥形旋转锉对运河进行测量,尺寸为#30。所有组均用盐水灌溉。第1组也使用EDTA 17%溶液(Pulpdent Corp,Watertown,MA)进行灌溉,第2组使用RC-Prep。在仪器前后进行X射线显微计算机断层扫描和工作长度测量。从仪器前和仪器后的扫描数据创建三维模型,并比较其体积变化。在运河的横截面切片中计算质心点,并通过测量仪器前和仪器后点之间的距离来确定运输。使用方差的单向分析(alpha = 0.05)和Tukey post hoc检验分析数据。结果:与第1组(P = .001)和对照组(P = .014)相比,第2组的转运较少。第一组和对照组的运输没有显着差异。相对于第2组(P = .004)和对照组(P = .022),第1组的运河体积增加。在工作长度上没有观察到显着差异。结论:在根管器械中使用螯合剂不会显着增加根尖运输。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号