In-vitro study comparing the self-adjusting file to the Vortex RTM rotary file with passive ultrasonic irrigation on the seal of root canal fillings in oval shaped canals.

机译:体外研究比较了自动调节锉刀和Vortex RTM旋转锉刀在被动式超声波冲洗下对椭圆形根管的根管充填物的密封效果。

获取原文
获取原文并翻译 | 示例

摘要

The purpose of this microleakage study was to use the glucose penetration model to compare the cleaning and shaping efficacy of the self-adjusting file system (SAF) to the Vortex® rotary file augmented with passive ultrasonic irrigation (PUI) in long, oval shaped canals. A total of 44 single rooted, straight canals of extracted human teeth were used in this study with 22 samples in each of the two groups. All samples were subject to their respective instrumentation protocol and obturated with a continuous wave technique using AH plus® sealer. Using the glucose penetration model, a 1.5 kPa of hydrostatic pressure pushed 1 mol/L of glucose solution down the root. Duplicate 12 µL aliquots were collected from the reservoir of each sample on days 1, 2, 7, 14, and 28. In each sample, the level of glucose was determined based on the glucose-oxidase reaction using the QuantiChrom™ Glucose Assay Kit. The concentration of glucose was determined spectrophotometrically at 630nm. Results showed that the SAF leaked significantly more in days 1, 2, 7, and 14 than the Vortex ® with PUI. The overall statistical significance was calculated using the ANOVA test, yielding a p-value of 0.0064. In conclusion, the SAF did not result in improved sealing outcomes when compared to the Vortex ® rotary file used in conjunction with PUI. According to the results of this study, the SAF did not offer an improved method to cleaning and shaping long, oval shaped canals.
机译:这项微渗漏研究的目的是使用葡萄糖渗透模型来比较自我调节锉刀系统(SAF)和椭圆形长管中被动超声冲洗(PUI)增强的Vortex®旋转锉刀的清洁和定型效果。在这项研究中,总共使用了44条单根,拔出的人类牙齿的直管,两组中各有22个样品。所有样品均受其各自的仪器规程约束,并使用AHplus®密封剂通过连续波技术封闭。使用葡萄糖渗透模型,1.5 kPa的静水压将1 mol / L葡萄糖溶液推向根部。在第1、2、7、14和28天从每个样品的储液罐中收集一式两份的12 µL等分试样。在每个样品中,使用QuantiChrom™葡萄糖测定试剂盒根据葡萄糖氧化酶反应确定葡萄糖水平。用分光光度法在630nm处测定葡萄糖的浓度。结果表明,与带PUI的Vortex®相比,SAF在第1、2、7和14天泄漏明显更多。使用ANOVA检验计算总体统计显着性,得出p值为0.0064。总之,与与PUI一起使用的Vortex®旋转锉相比,SAF不会改善密封效果。根据这项研究的结果,SAF并没有提供一种改进的方法来清洁和塑造椭圆形的长运河。

著录项

  • 作者

    Pham, Tuyen T.;

  • 作者单位

    West Virginia University.;

  • 授予单位 West Virginia University.;
  • 学科 Health Sciences Dentistry.
  • 学位 M.S.
  • 年度 2012
  • 页码 56 p.
  • 总页数 56
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-17 11:42:39

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号