...
首页> 外文期刊>Journal of Endodontics: Official Journal of American Association of Endodontists >Does a combination of two radiographs increase accuracy in detecting acid-induced periapical lesions and does it approach the accuracy of cone-beam computed tomography scanning?
【24h】

Does a combination of two radiographs increase accuracy in detecting acid-induced periapical lesions and does it approach the accuracy of cone-beam computed tomography scanning?

机译:结合两个X射线照片是否可以提高检测酸诱导的根尖周病变的准确性,并达到锥束计算机断层扫描的准确性?

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Introduction: The purpose of this study was to determine whether the use of a combination of 2 images (storage phosphor plates [SPPs] and F-speed films [Eastman Kodak, Rochester, NY]) with a 10° difference in horizontal beam angulation resulted in better detectability of chemically created periapical defects than when only 1 image was used and whether a detectability as good as that achieved by limited cone-beam computed tomography (LCBCT) scanning could be achieved. Methods: Lesions were created by 1, 1.5, and 2 hours of acid application apical to extracted teeth in jaw specimens. After repositioning, teeth were radiographed with Accu-I-Tomo LCBCT, Digora Optime SPP system, and F-speed films. The SPPs and films were exposed at 0° and 10° horizontal angulations. The diagnostic accuracy (Az) was compared using 2-way analysis of variance; pair-wise comparisons were performed using the post hoc t test. Kappa was used to measure interobserver agreement. Results: A combination of 2 exposures with a 10° difference in horizontal angulation caused an increase, although not statistically significant, in the accuracy of both films and SPPs for all acid durations (P >.05) compared with when only 1 exposure was used. The accuracy did not approach that of LCBCT. Conclusions: Using a combination of 2 exposures instead of 1 did not significantly increase the accuracy in detecting acid-induced lesions at the apices of single-rooted premolars. The accuracy of LCBCT was superior.
机译:简介:本研究的目的是确定是否使用水平方向上的角度相差10°的两个图像(存储荧光板[SPPs]和F-speed胶片[Eastman Kodak,Rochester,NY])的组合与仅使用1张图像相比,化学产生的根尖周缺损具有更好的可检测性,并且能否实现与有限的锥形束计算机断层扫描(LCBCT)扫描一样的可检测性。方法:通过在下颌标本中拔出的牙齿顶端施加1、1.5和2小时的酸液,可形成病变。重新定位后,用Accu-I-Tomo LCBCT,Digora Optime SPP系统和F速胶片对牙齿进行射线照相。将SPP和胶片以0°和10°水平角曝光。使用方差的2通分析比较诊断准确性(Az);使用事后检验进行成对比较。 Kappa用于衡量观察员之间的协议。结果:与仅使用一次曝光相比,两次曝光在水平角度上相差10°的组合导致在所有酸持续时间内(P> .05)胶片和SPP的精度均提高了,尽管在统计学上并不显着。 。准确性未达到LCBCT的准确性。结论:使用2次曝光而不是1次曝光的组合并不能显着提高单根前磨牙尖端酸致病变的检测准确性。 LCBCT的准确性更高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号