AIM: To investigate the effect of reducing limited-volume cone-beam computed tomographs arc of rotation from 360 degrees to 180 degrees on the ability to diagnose small, artificially created apical lesions. METHODOLOGY: Small, artificial apical bone lesions were prepared with a bur in the apical region of the distal root of ten mandibular first molars, in human dry mandibles. The jaws were scanned in a fixed position with limited-volume CBCT making a 360 degrees and 180 degrees arc of rotation, before and after each periapical lesion had been created. A 4 x 4 cm field of view was used at 90 kV, with a current of 4 mA. Ten examiners blinded to the scan parameters and controls scored the presence/absence of bone lesions. Intra-examiner reliability was determined after 2 weeks, reviewing half the data set. Statistical analyses with paired t-tests determined the diagnostic accuracy of the two modalities (360 degrees vs. 180 degrees ) in terms of sensitivity, specificity, receiver operating characteristic area under the curve, positive predictive values and negative predictive values. RESULTS: The mean values for sensitivity of the 360 degrees and 180 degrees scans were 0.91 and 0.89, respectively; their mean specificities were 0.73. No significant differences were reflected in the statistical analyses. CONCLUSIONS: Both 360 degrees and 180 degrees cone-beam computed tomography scans yielded similar accuracy in the detection of artificial bone lesions. The use of 180 degrees scans might be advisable to reduce the radiation dose to the patient in line with the ICRP guidance to use as low a dosage as reasonably achievable.
机译:目的:研究将有限体积的锥形束计算机断层扫描仪的旋转弧度从360度减少到180度对诊断较小的人工创建的根尖病变的能力的影响。方法:在干燥的下颌骨中,用十个下颌第一磨牙的远侧根部的根尖上的钻针制备小而人造的根尖骨病变。在创建每个根尖周病变之前和之后,使用有限体积的CBCT在固定位置扫描颌骨,并进行360度和180度旋转弧度。在90 kV下使用4 x 4 cm的视场,电流为4 mA。十名检查员对扫描参数不了解,对照组对骨病变的存在/不存在进行了评分。 2周后确定检查者内部的可靠性,检查数据集的一半。带有配对t检验的统计分析在灵敏度,特异性,曲线下的受体工作特征区域,阳性预测值和阴性预测值方面确定了两种方法(360度vs. 180度)的诊断准确性。结果:360度和180度扫描的灵敏度平均值分别为0.91和0.89;其平均特异性为0.73。统计分析未反映出显着差异。结论:360度和180度的锥形束计算机断层扫描可以在人造骨病变的检测中获得相似的准确性。最好采用180度扫描,以根据ICRP指南减少对患者的辐射剂量,以合理使用尽可能低的剂量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号