首页> 外文期刊>Journal of Endodontics: Official Journal of American Association of Endodontists >Comparison of endotoxin levels in previous studies on primary endodontic infections.
【24h】

Comparison of endotoxin levels in previous studies on primary endodontic infections.

机译:先前有关原发性牙髓感染的研究中内毒素水平的比较。

获取原文
获取原文并翻译 | 示例
       

摘要

BACKGROUND: This study was performed to determine which of the quantitative methods, namely, chromogenic endpoint, chromogenic kinetic, and turbidimetric kinetic ones, best fit for the analysis of primary endodontic infections. METHODS: Twenty-one root canals with apical periodontitis were sampled with paper points. The same sample was analyzed by means of the endpoint chromogenic Limulus amebocyte lysate (LAL) assay (QCL), quantitative kinetic chromogenic LAL assay (KQCL), and kinetic turbidimetric LAL assay (Turbidimetric). RESULTS: All three LAL methods were effective in the recovery of endotoxin from root canal infection. Regardless of the method tested, endotoxin was detected in 100% of the root canals (21/21). The KQCL assay yielded a median value of endotoxin of 7.49 EU/mL, close to and not significantly different from those for the turbidimetric test (9.19 EU/mL) (both kinetic methods) (p > 0.05). In contrast, the endpoint QCL showed a median value of 34.20 EU/mL (p < 0.05). The comparison of the three methods revealed that both turbidimetric and KQCL methods were more precise, with best reproducibility (the coefficient variation between analysis of the root canal and its duplicate was lower than 10%). The inhibition/enhancement assay indicated a good interaction between the root canal samples with the turbidimetric method. CONCLUSION: This study has revealed that quantitative kinetic-turbidimetric and kinetic-chromogenic LAL methods are best fitted for the analysis of endotoxins in root canal infection, both being more precise and allowing better reproducibility compared with the endpoint-QCL assay.
机译:背景:进行这项研究是为了确定哪种定量方法,即生色终点法,生色动力学法和比浊动力学法,最适合于原发性牙髓感染的分析。方法:对21例根尖性牙周炎的根管进行取样。借助终点生色am血红细胞溶胞产物(LAL)分析(QCL),定量动力学生色LAL分析(KQCL)和动力学比浊LAL分析(Turbidimetric)分析同一样品。结果:三种LAL方法均能有效地从根管感染中恢复内毒素。无论采用哪种测试方法,均会在100%的根管中检测到内毒素(21/21)。 KQCL分析得出的内毒素中位值为7.49 EU / mL,与浊度测试的结果(9.19 EU / mL)相近且无显着差异(两种动力学方法均如此)(p> 0.05)。相反,终点QCL显示的中值为34.20 EU / mL(p <0.05)。三种方法的比较表明,浊度法和KQCL法均较精确,重现性最好(根管分析和重复测量之间的系数差异小于10%)。抑制/增强试验表明,比浊法在根管样品之间具有良好的相互作用。结论:这项研究表明定量动力学比浊法和动力学显色LAL法最适合分析根管感染中的内毒素,与终点-QCL法相比,它们更精确且可重复性更高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号