Problems associated with the large file sizes of digital mammograms have impeded the integration of digital mammography with picture archiving and communications systems. Digital mammograms irreversibly compressed by the novel wavelet Access Over Network (AON) compression algorithm were compared with lossless-compressed digital mammograms in a blinded reader study to evaluate the perceived sufficiency of irreversibly compressed images for comparison with next-year mammograms. Fifteen radiologists compared the same 100 digital mammograms in three different comparison modes: lossless-compressed vs 20:1 irreversibly compressed images (mode 1), lossless-compressed vs 40:1 irreversibly compressed images (mode 2), and 20:1 irreversibly compressed images vs 40:1 irreversibly compressed images (mode 3). Compression levels were randomly assigned between monitors. For each mode, the less compressed of the two images was correctly identified no more frequently than would occur by chance if all images were identical in compression. Perceived sufficiency for comparison with next-year mammograms was achieved by 97.37% of the lossless-compressed images and 97.37% of the 20:1 irreversibly compressed images in mode 1, 97.67% of the lossless-compressed images and 97.67% of the 40:1 irreversibly compressed images in mode 2, and 99.33% of the 20:1 irreversibly compressed images and 99.19% of the 40:1 irreversibly compressed images in mode 3. In a random-effect analysis, the irreversibly compressed images were found to be noninferior to the lossless-compressed images. Digital mammograms irreversibly compressed by the wavelet AON compression algorithm were as frequently judged sufficient for comparison with next-year mammograms as lossless-compressed digital mammograms.
机译:与数字乳房X线照片的大文件大小相关的问题阻碍了数字乳房X线照片与图片存档和通信系统的集成。在盲人阅读器研究中,将通过新型小波网络访问(AON)压缩算法不可逆压缩的数字乳房X线照片与无损压缩数字乳房X线照片进行比较,以评估不可逆压缩图像的感知充足性,以与下一年的乳房X射线照片进行比较。 15位放射科医生在三种不同的比较模式下比较了相同的100幅乳腺X光照片:无损压缩vs. 20:1不可逆压缩图像(模式1),无损压缩vs 40:1不可逆压缩图像(模式2)和20:1不可逆压缩图片与40:1不可逆压缩的图片(模式3)。压缩级别是在监视器之间随机分配的。对于每种模式,正确识别两个图像中压缩程度较低的频率不会比所有图像压缩相同时偶然发生的频率高。在模式1下,无损压缩图像的97.37%和20:1不可逆压缩图像的97.37%,可以与下一年度的乳房X线照片进行比较,可感知的充分性达到无损压缩图像的97.67%和40:40的97.67%。模式2下为1不可逆压缩图像,模式3下为20:1不可逆压缩图像的99.33%和40:1不可逆压缩图像的99.19%。在随机效应分析中,发现不可逆压缩的图像不逊色。到无损压缩的图像。小波AON压缩算法不可逆地压缩的数字乳房X线照片与无损压缩数字乳房X线照片一样,经常被认为足以与明年的乳房X线照片进行比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号