BACKGROUND: Adiponectin, present in different multimeric forms in circulation, is increasingly used in clinical settings as a cardiometabolic marker. The development of several commercially available enzyme-linked immunosorbent assays (ELISA) has allowed for the widespread measurement of adiponectin in research as well as in clinical practice. The comparative performance of these assays is thus an issue of major relevance. METHODS: The analytical performance of four different ELISAs (LINCO, B-Bridge, SPIbio and ALPCO) was evaluated. Samples from 102 cardiac patients and 40 healthy subjects were tested using LINCO and ALPCO. The latter is able to measure the concentrations of multimers. For the multimer assay, an error propagation study was performed. A subset of subjects was tested by all four ELISAs for comparison purposes. RESULTS: Bland-Altman plots revealed differences between the results of the four ELISAs, mainly for ALPCO. However, a strong correlation between the different ELISAs (ALPCO, r=0.83; B-Bridge, r=0.98; SPIbio, r=0.91 vs. LINCO) was observed. Total adiponectin measured by LINCO showed a better association with cardiac disease [receiver-operating characteristic (ROC) curves] than total and high molecular weight adiponectin measured by ALPCO. CONCLUSIONS: The results of this study contribute to a better understanding of the methodological features of the several ELISAs, and help in the evaluation and comparison of the relative results.
机译:背景:脂联素以不同的多聚体形式存在于循环中,在临床上越来越多地用作心脏代谢指标。几种可商购的酶联免疫吸附测定(ELISA)的发展使得脂联素在研究和临床实践中得到了广泛的测量。因此,这些测定法的比较性能是主要相关的问题。方法:评估了四种不同ELISA(LINCO,B-Bridge,SPIbio和ALPCO)的分析性能。使用LINCO和ALPCO对来自102名心脏病患者和40名健康受试者的样品进行了测试。后者能够测量多聚体的浓度。对于多聚体测定,进行了误差传播研究。为了比较目的,通过所有四种ELISA测试了受试者的一个子集。结果:Bland-Altman图揭示了四种ELISA结果之间的差异,主要针对ALPCO。然而,观察到不同ELISA之间有很强的相关性(ALPCO,r = 0.83; B-Bridge,r = 0.98; SPIbio,r = 0.91 vs. LINCO)。 LINCO测定的总脂连蛋白与心脏病[受试者工作特征(ROC)曲线]的关联性比ALPCO测定的总脂联素和高分子量脂联素更好。结论:本研究的结果有助于更好地理解几种ELISA的方法学特征,并有助于评估和比较相对结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号