首页> 外文期刊>Clinical chemistry and laboratory medicine: CCLM >A simple liquid chromatography-tandem mass spectrometry method for measuring metanephrine and normetanephrine in urine.
【24h】

A simple liquid chromatography-tandem mass spectrometry method for measuring metanephrine and normetanephrine in urine.

机译:一种简单的液相色谱-串联质谱法测定尿中的间肾上腺素和去甲肾上腺素。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

BACKGROUND: Measuring urinary fractionated metanephrines is one of the initial tests in the diagnosis of pheochromocytoma. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) represents the most specific and accurate technology for this purpose. The goal of this work was to develop a simple LC-MS/MS method for measuring metanephrines in urine. METHODS: Each urine sample was complexed with diphenylboronic acid, and purified on a Bond-Elute Plexa cartridge. The extract was concentrated and analyzed on a short Atlantis T3 column in 8.5 min. Metanephrines and their deuterated internal standards were monitored in positive electrospray ionization mode by multiple reaction monitoring. RESULTS: Ion suppression was observed, but was compensated for by the respective internal standard. The analytical measurement range was 0.2-27.4 mumol/L and 0.3-14.6 mumol/L for metanephrine and normetanephrine, respectively. The intra-assay and total coefficient of variation throughout the linear ranges was 2.03%-2.11% and 2.20%-3.80% for metanephrine, and 4.50%-8.09% and 9.00%-10.00% for normetanephrine, respectively. Comparison with a commercial HPLC method using patient samples (n=65) by Passing-Bablok regression showed a slope of 1.000 and 1.014, y-intercept of -0.080 and -0.067, a correlation coefficient of 0.8830 and 0.9022, and a mean difference of 14.0% and -0.43% for metanephrine and normetanephrine, respectively. CONCLUSIONS: This simple method for urine metanephrines is suitable for clinical use.
机译:背景:测量尿中分离的肾上腺素是诊断嗜铬细胞瘤的初步方法之一。液相色谱-串联质谱(LC-MS / MS)代表了最具体,最准确的技术。这项工作的目的是开发一种简单的LC-MS / MS方法来测量尿液中的肾上腺素。方法:将每个尿液样品与二苯硼酸复合,并在Bond-Elute Plexa柱上纯化。浓缩提取物,并在短的Atlantis T3色谱柱上进行8.5分钟的分析。通过多反应监测以正电喷雾电离模式监测间肾上腺素及其氘代内标。结果:观察到离子抑制,但被各自的内标所补偿。间肾上腺素和去甲肾上腺素的分析测量范围分别为0.2-27.4μmol/ L和0.3-14.6μmol/ L。整个线性范围内的测定内变异系数和总变异系数对于甲基肾上腺素分别为2.03%-2.11%和2.20%-3.80%,对于去甲肾上腺素分别为4.50%-8.09%和9.00%-10.00%。通过Passing-Bablok回归与使用患者样本(n = 65)的商业HPLC方法进行比较,显示斜率1.000和1.014,y截距为-0.080和-0.067,相关系数为0.8830和0.9022,平均差为肾上腺素和去甲肾上腺素分别为14.0%和-0.43%。结论:这种简单的尿中肾上腺素测定方法适合临床使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有