首页> 外文期刊>Analytical and bioanalytical chemistry >Simple, rapid, and cost-effective microextraction by the packed sorbent method for quantifying of urinary free catecholamines and metanephrines using liquid chromatography-tandem mass spectrometry and its application in clinical analysis
【24h】

Simple, rapid, and cost-effective microextraction by the packed sorbent method for quantifying of urinary free catecholamines and metanephrines using liquid chromatography-tandem mass spectrometry and its application in clinical analysis

机译:用液相色谱 - 串联质谱法定量尿液式加入的吸附剂和MetoPhrines的填充吸附剂方法简单,快速,经济高效的微萃取方法及其在临床分析中的应用

获取原文
获取原文并翻译 | 示例
           

摘要

Pheochromocytoma and paraganglioma (PPGL) are rare neuroendocrine tumors arising from adrenal and extra-adrenal chromaffin cells. They produce excessive amounts of catecholamines and their metabolites. A newly analytical procedure based on the semi-automated microextraction by packed sorbent (MEPS) technique, using a digitally controlled syringe (eVol) combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS), was developed to quantify free urinary catecholamines and metanephrines. The important parameters affecting MEPS performance, namely the type of sorbent material (porous graphitized carbon (PGC), polar enhanced polymer (PEP), cation-exchange (CX) and C18), number of extraction cycles, and elution solvent system, were evaluated. The optimal experimental conditions involved the loading of sample mixture in seven extraction cycles through a C18 sorbent in a MEPS syringe, followed by using elution solutions (water/acetonitrile/formic acid, 95/4.75/0.25). The entire sample preparation took about 4?min. Chromatographic separation was well achieved with an HSS PFP column using the gradient elution. The linearity range of the method was 0.167–33.4?ng/mL for epinephrine, 0.650–130?ng/mL for norepinephrine, 1.53–306?ng/mL for dopamine, 1.34–268?ng/mL for metanephrine, 3.43–686?ng/mL for normetanephrine, and 1.33–265?ng/mL for 3-methoxytyramine. The intra- and interassay precisions were ≤?12.8%, and the respective accuracies were 88.4–112.0% and 89.0–109.5%. The carryover and sample stability without acidification were also investigated. Validation using clinical urine specimens showed that the proposed method had higher sensitivity compared with other urinary biochemical tests. The developed MEPS-LC-MS/MS method was simple, fast, and cost-effective; it helped to obtain information about multiple metabolites. It is applicable in routine clinical laboratories for the screening of PPGL.Graphical abstract
机译:Pheochromytoma和Paraganglioma(PPGL)是由肾上腺和外肾上腺铬细胞产生的罕见神经内分泌肿瘤。它们产生过量的儿茶酚胺和它们的代谢物。通过填充吸附剂(MEPS)技术的基于半自动微萃取的新分析过程,使用经量控制的注射器(EVOL)与液相色谱 - 串联质谱(LC-MS / MS)结合,以量化游离尿道酰胺和metanephrines。影响MEPS性能的重要参数,即吸附剂材料的类型(多孔石墨化碳(PGC),极性增强聚合物(PEP),阳离子交换(CX)和C18),提取循环的数量和洗脱溶剂系统。最佳的实验条件涉及通过MEPS注射器中的C18吸附剂在七种提取循环中加载样品混合物,然后使用洗脱溶液(水/乙腈/甲酸,95 / 4.75 / 0.25)。整个样品制剂花了大约4?分钟。通过使用梯度洗脱,通过HSS PFP柱达到色谱分离。该方法的线性范围为0.167-33.4〜肾上腺素,0.650-130〜Norepinephrine的Ng / ml,1.53-306〜ml用于多巴胺,1.34-268〜Metanephrine的Ng / ml,3.43-686 Ng / ml对于Nametanephrine,1.33-265〜3-甲氧基氧嘧啶的Ng / ml。介乎和介的矫正均≤12.8%,相应的精度为88.4-112.0%和89.0-109.5%。还研究了没有酸化的携带和样品稳定性。使用临床尿液试样的验证表明,与其他尿化生物化学测试相比,该方法的敏感性较高。开发的MEPS-LC-MS / MS方法简单,快速,成本效益;它有助于获取有关多个代谢物的信息。它适用于常规临床实验室,用于筛查PPGL.Graphical摘要

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号