A simple, precise and accurate high-performance liquid chromatography (HPLC) method using ultraviolet (UV) detection has been developed for simultaneous determination of carbapenem antibiotics: imipenem, meropenem and ertapenem in human plasma. Samples were spiked with ceftazidime as internal standard and proteins were precipitated by acetonitrile. Separation was achieved on a C8 column with a mobile phase composed of phosphate buffer 0.1 M (pH 6.8) and methanol in gradient elution mode. Detection was performed at 298 nm. Calibration curves were linear from 0.5 to 80 mg/L for each compound, with Correlation coefficients over 0.997. Intra- and inter-day validation studies showed accuracy between -4.5 and 8.1% and precision below 10.4%. Mean recoveries were 82.2,90.8 and 87.7% for imipenem, meropenem and ertapenem. respectively. This method provides a useful tool for the therapeutic drug monitoring of carbapenems. (c) 2008 Elsevier B.V. All rights reserved.
机译:已经开发了一种使用紫外线(UV)检测的简单,准确和准确的高效液相色谱(HPLC)方法,用于同时测定人血浆中的碳青霉烯类抗生素:亚胺培南,美洛培南和厄他培南。样品中以头孢他啶为内标加标,蛋白质通过乙腈沉淀。在C8色谱柱上进行分离,该色谱柱的流动相由0.1 M磷酸盐缓冲液(pH 6.8)和甲醇组成,梯度洗脱。在298nm处进行检测。每种化合物的校正曲线在0.5至80 mg / L之间呈线性,相关系数超过0.997。日内和日间验证研究显示准确度在-4.5至8.1%之间,准确度在10.4%以下。亚胺培南,美罗培南和厄他培南的平均回收率分别为82.2、90.8和87.7%。分别。该方法为监测碳青霉烯类药物提供了有用的工具。 (c)2008 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号