首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >INTERLABORATORY EVALUATION OF AN OFF-LINE SUPERCRITICAL FLUID EXTRACTION AND GAS CHROMATOGRAPHY WITH ATOMIC EMISSION DETECTION METHOD FOR THE DETERMINATION OF ORGANOTIN COMPOUNDS IN SOIL AND SEDIMENTS
【24h】

INTERLABORATORY EVALUATION OF AN OFF-LINE SUPERCRITICAL FLUID EXTRACTION AND GAS CHROMATOGRAPHY WITH ATOMIC EMISSION DETECTION METHOD FOR THE DETERMINATION OF ORGANOTIN COMPOUNDS IN SOIL AND SEDIMENTS

机译:离线超临界流体萃取-气相色谱原子发射光谱法测定土壤和沉积物中的有机锡含量。

获取原文
获取原文并翻译 | 示例
           

摘要

A collaborative study was Conducted, with eight laboratories participating, to determine the method accuracy and precision of an off-line supercritical fluid extraction (SFE) method for organotin compounds. This method involves extraction of organotin compounds from solid matrixes with supercritical carbon dioxide, modified with 5% methanol, at 450 atm and 60 degrees C for 20 min in the static mode followed by 30 min in the dynamic mode. The extracted material was collected in either methylene chloride or on a C-18-bonded silica trap followed by a methylene chloride rinse. The extracted material was derivatized with pentyl magnesium bromide and analyzed by gas chromatography with atomic emission detection (GC-AED). The study design was based on the AOAC blind-replicate design with balanced replicates. The study samples consisted of three solid matrixes that were spiked with organotin compounds at 1000 ng/g (as Sn) and one unspiked matrix that contained dibutyltin and tributyltin compounds at independently determined levels. The results of this interlaboratory study indicate that the SFE method works satisfactorily for the tri- and tetra-substituted organotin compounds but that the di- and mono-substituted organotin compounds are quite difficult to extract under these conditions. Higher pressures and different modifiers may be required to enable extraction of the mono- and di-substituted organotin compounds from soils and sediments. (C) 1997 Elsevier Science B.V
机译:进行了一项合作研究,有八个实验室参与其中,以确定有机锡化合物的离线超临界流体萃取(SFE)方法的方法准确性和精密度。该方法涉及在静态模式下,在450 atm和60摄氏度下,用超临界二氧化碳(经5%甲醇改性)从固体基质中提取有机锡化合物20分钟,然后在动态模式下30分钟。将提取的物质收集在二氯甲烷中或在C-18键合的硅胶阱上,然后用二氯甲烷冲洗。提取的物质用戊基溴化镁衍生化,并通过带有原子发射检测的气相色谱仪(GC-AED)进行分析。研究设计基于具有平衡重复的AOAC盲重复设计。研究样品由三种固体基质和1000 ng / g(以Sn计)的有机锡化合物加标组成,以及一种未加标的基质,其中含有独立确定含量的二丁基锡和三丁基锡化合物。实验室间研究的结果表明,SFE方法对于三和四取代的有机锡化合物令人满意,但在这些条件下很难提取二和单取代的有机锡化合物。可能需要更高的压力和不同的改性剂,才能从土壤和沉积物中提取单取代和双取代的有机锡化合物。 (C)1997年Elsevier Science B.V

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号