首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Single-laboratory validation of a gas chromatography-mass spectrometry method for quantitation of 15 European priority polycyclic aromatic hydrocarbons in spiked smoke flavourings
【24h】

Single-laboratory validation of a gas chromatography-mass spectrometry method for quantitation of 15 European priority polycyclic aromatic hydrocarbons in spiked smoke flavourings

机译:气相色谱-质谱法定量加标烟熏香料中15种欧洲优先多环芳烃的实验室验证

获取原文
获取原文并翻译 | 示例
           

摘要

An existing method was adapted to the purpose and validated in-house according to the IUPAC harmonised guideline for the determination of 15 EU priority polycyclic aromatic hydrocarbons (PAHs) in primary smoke condensates (PSCs) that are used to produce smoke flavourings for human consumption. Limits of detection (LOD) varied between 0.1 and 1.3 mu g/kg, limits of quantitation (LOQ) between 0.5 and 4 mu g/kg for the various PAHs in PSCs. The coefficient of variance of the repeatability was between 0.7% (benzo[a]pyrene) and 30% (dibenzo[a,h]pyrene) relative standard deviation, depending on the analyte. The recoveries varied between 100 and 102% (dibenzo[a,l]pyrene) and 69-83% (dibenzo[a,h]pyrene) over the analytical range of 5-35 mu g/kg. (c) 2005 Elsevier B.V. All rights reserved.
机译:现有的方法已针对该目的进行了调整,并根据IUPAC协调指南进行了内部验证,该指南用于确定主要烟雾冷凝物(PSC)中15种欧盟优先使用的多环芳烃(PAH),这些物质用于生产供人食用的烟用香精。 PSC中各种PAH的检出限(LOD)在0.1至1.3μg / kg之间变化,定量限(LOQ)在0.5至4μg / kg之间。取决于分析物,可重复性的方差系数相对标准偏差在0.7%(苯并[a] py)和30%(二苯并[a,h] py)之间。在5-35μg / kg的分析范围内,回收率在100%和102%(二苯并[a,l] py)和69-83%(二苯并[a,h] py)之间变化。 (c)2005 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号