A novel stability-indicating ultra performance liquid chromatographic (UPLC) method has been developed for quantitative determination of nilotinib hydrochloride in active pharmaceutical ingredients along with four impurities (imp-1, imp-2, imp-3 and imp-4). The method is applicable to the quantification of related compounds and assay of nilotinib hydrochloride drug. Efficient chromatographic separation was achieved on a Shim-pack XR-ODS II, 75 × 3.0 mm, 1.8-μm column with a gradient mobile phase combination. Quantification was carried at 260 nm at a flow rate of 0.6 mL min~(-1). Stress degradation conditions were established for nilotinib hydrochloride by subjecting it to acid, base, oxidation, humidity, thermal and photolysis. The stress samples were assayed against a qualified reference standard and the mass balance was found close to 97.0%. The developed UPLC method was validated according to the present International Conference on Harmonisation guidelines for specificity, detection limit, quantitation limit, linearity, accuracy, precision, intermediate precision and robustness. The resolution between nilotinib hydrochloride and four potential impurities is found to be >2.0. Regression analysis shows as r value (correlation coefficient) of >0.999 for nilotinib hydrochloride and four potential impurities.
机译:已开发出一种新颖的稳定性指示超高效液相色谱(UPLC)方法,用于定量测定活性药物成分中的盐酸尼洛替尼以及四种杂质(imp-1,imp-2,imp-3和imp-4)。该方法适用于相关化合物的定量和盐酸尼洛替尼药物的测定。在带有梯度流动相组合的75×3.0 mm,1.8μmShim-pack XR-ODS II色谱柱上实现了高效色谱分离。定量在260 nm处以0.6 mL min〜(-1)的流速进行。通过使盐酸尼洛替尼经受酸,碱,氧化,湿度,热和光解作用,建立了应力降解条件。根据合格的参考标准对应力样品进行了分析,发现质量平衡接近97.0%。根据当前的国际协调大会指南,针对特异性,检测限,定量限,线性,准确度,精密度,中间精密度和鲁棒性,对开发的UPLC方法进行了验证。盐酸尼洛替尼与四种潜在杂质之间的分离度> 2.0。回归分析显示,盐酸尼洛替尼和四种潜在杂质的r值(相关系数)> 0.999。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号