首页> 外文期刊>Journal of computer assisted tomography >Vascular suppression technique in MRI using Gd-DTPA: improving image quality of MR myelography.
【24h】

Vascular suppression technique in MRI using Gd-DTPA: improving image quality of MR myelography.

机译:使用Gd-DTPA进行MRI的血管抑制技术:提高MR脊髓成像的图像质量。

获取原文
获取原文并翻译 | 示例
       

摘要

PURPOSE: To delete signals of juxta-thecal venous structures on MR myelograms, we evaluated the potential of Gd-DTPA as a negative contrast material in experiments and actual MR myelograms. METHOD: We measured the signals of Gd-DTPA solutions of various concentrations on T2-weighted turbo-SE and turbo-STIR images. The experiments revealed that 0.83 mmol/L Gd-DTPA worked as a negative contrast material in turbo-STIR. Subsequently, we obtained turbo-STIR myelograms of 31 patients who complained of lumbago or sciatica before and after intravenous administration of 0.15 mmol/kg Gd-DTPA, which was presumed to provide the optimal plasma density in vivo. RESULTS: On postcontrast MR myelograms, the venous signals around the thecal sac decreased remarkably in almost all the cases as compared with precontrast images. In these cases, the nerve roots could be observed clearly. CONCLUSION: Gd-DTPA can work as a negative contrast material in turbo-STIR sequences. This characteristic should be used to improve the image quality of MR myelography using turbo-STIR.
机译:目的:为了删除MR脊髓造影上的近鞘静脉结构的信号,我们评估了Gd-DTPA在实验和实际MR脊髓造影中作为阴性造影剂的潜力。方法:我们在T2加权的turbo-SE和turbo-STIR图像上测量了各种浓度的Gd-DTPA溶液的信号。实验表明,0.83 mmol / L Gd-DTPA是turbo-STIR中的负对比材料。随后,我们获得了31例在静脉内施用0.15 mmol / kg Gd-DTPA前后抱怨腰痛或坐骨神经痛的患者的Turbo-STIR脊髓造影照片,推测这可提供体内最佳血浆密度。结果:在对比后的MR脊髓造影上,与对比前的图像相比,在几乎所有情况下,囊囊周围的静脉信号均显着下降。在这些情况下,可以清楚地观察到神经根。结论:Gd-DTPA可以作为Turbo-STIR序列中的负对比材料。此特征应用于改善使用turbo-STIR的MR脊髓造影的图像质量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号