...
首页> 外文期刊>Journal of cataract and refractive surgery >Comparative analysis of the visual and refractive outcomes of an aspheric diffractive intraocular lens with and without toricity
【24h】

Comparative analysis of the visual and refractive outcomes of an aspheric diffractive intraocular lens with and without toricity

机译:具有和不具有复曲面的非球面衍射人工晶状体的视觉和屈光结果的比较分析

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Purpose To analyze and compare the postoperative visual and refractive outcomes and patients' visual satisfaction after implantation of an aspheric or an aspheric toric multifocal diffractive intraocular lens (IOL) in eyes with equivalent biometric characteristics. Setting Private clinic, Munich, Germany. Design Comparative case series. Methods Patients having cataract surgery were assigned to 1 of 2 groups: aspheric, which had AT Lisa 809M IOL implantation, and aspheric toric, which had AT Lisa 909M IOL implantation (corneal toricity ≥0.75 diopter [D]). Visual and refractive postoperative outcomes were evaluated, as was the patient's ability to perform daily tasks related to vision and the incidence of photic phenomena. Results The aspheric group comprised 77 eyes (42 patients) and the aspheric toric group, 26 eyes (17 patients). A significant improvement in corrected distance and near visual acuity was observed postoperatively in both groups, as was a significant reduction in the astigmatic component J0 (P<.01). The aspheric toric group had significantly better uncorrected intermediate visual acuity (P=.01). In both groups, the postoperative astigmatic power vectors and spherical equivalent were within ±0.50 D in 100% of eyes and in more than 88% of eyes, respectively. No statistically significant differences were found in any subjective patient questionnaire item. There was no difference in the incidence of photic phenomena between the groups (P≥0.16). Conclusion The addition of a toric surface to the aspheric diffractive multifocal platform resulted in a comparable visual performance and ability to perform visual tasks. Financial Disclosure The author has no financial or proprietary interest in any material or method mentioned.
机译:目的分析和比较在具有等效生物特征的眼睛中植入非球面或非球面复曲面多焦点衍射人工晶状体(IOL)后的术后视觉和屈光结果以及患者的视觉满意度。设置私人诊所,德国慕尼黑。设计比较案例系列。方法将白内障手术患者分为2组中的1组:非球面植入AT Lisa 809M IOL,非球面复曲面植入AT Lisa 909M IOL(角膜复曲面≥0.75屈光度[D])。评估患者的视觉和屈光术后结局,以及患者执行与视觉和光合现象发生率相关的日常任务的能力。结果非球面组77只眼(42例),非球面复曲面组26只眼(17例)。两组术后矫正距离和近视敏度均有显着改善,散光分量J0显着减少(P <.01)。非球面复曲面组的未矫正中间视力明显更好(P = .01)。两组的术后散光度数矢量和球面等效图像分别在100%的眼睛和88%以上的眼睛中在±0.50 D以内。在任何主观患者调查表项目中均未发现统计学上的显着差异。两组之间光合现象的发生率无差异(P≥0.16)。结论在非球面衍射多焦点平台上增加了复曲面表面,从而产生了可比的视觉性能和执行视觉任务的能力。财务披露作者对所提及的任何材料或方法均没有财务或所有权利益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号