The Shead et al. article about an improvement to the SRK/T formula, describes a method to remove the "cusp characteristic" from the calculated intraocular lens (IOL) power curve as well as reduce an apparent small linear bias in the corneal height as a function of the mean corneal power. Figures 4 and 7 in the article nicely identify these issues. Based on a large sample of cases, Shead et al. state that with the SRK/T formula, 98% of eyes were within +-1.00 D and 78.7% were within +-0.50 D of the predicted outcome compared with 98.5% and 80.9%, respectively, with the T2 modification. They also state that the mean absolute prediction error was 0.3229 D with the SRK/T formula compared with 0.30,64 D with the T2 modification.
机译:Shead等。关于SRK / T公式改进的文章描述了一种方法,该方法可从计算的人工晶状体(IOL)屈光度曲线中删除“尖点特征”,并减少作为平均值函数的角膜高度的明显小线性偏差角膜力量。本文中的图4和7很好地标识了这些问题。基于大量的案例,Shead等人。指出,使用SRK / T公式,有98%的眼睛在预测结果的+ -1.00 D之内,有78.7%的眼睛在预测结果的+ -0.50 D之内,而使用T2修改的分别为98.5%和80.9%。他们还指出,SRK / T公式的平均绝对预测误差为0.3229 D,而T2修正的平均绝对预测误差为0.30,64D。