首页> 外文期刊>Clinical biomechanics >Investigation into the effect of varus-valgus orientation on load transfer in the resurfaced femoral head: a multi-femur finite element analysis.
【24h】

Investigation into the effect of varus-valgus orientation on load transfer in the resurfaced femoral head: a multi-femur finite element analysis.

机译:研究内翻-外翻方向对股骨头表面负荷转移的影响:多股有限元分析。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Femoral head resurfacing is a popular procedure for younger active hip replacement patients. Whilst the current generation of metal-on-metal resurfacing arthroplasties appear to have cured the osteolysis problems that plagued earlier resurfacing implants, fracture of the femoral head and aseptic loosening are still factors of concern in its survivorship. Several studies have shown a tendency towards failure in resurfaced femurs where the implant has been set at a varus angle. This work aims to investigate the influence of varus-valgus orientation on load transfer within the resurfaced proximal femur. METHODS: This study uses Computer Tomography based finite element analysis to determine the effect of implant orientation on load transfer in the proximal femur with respect to the intact femur. A group of 16 femurs were studied to take into account inter-patient variation; four models were produced for each femur, one of the intact femur, one resurfaced with the implant set inline with the femoral neck and one each representing varus and valgus implant alignment. FINDINGS: Results showed the valgus aligned resurfaced femur to produce strain patterns more akin to the intact femur. As the implant's angle to the femoral shaft increases from varus to valgus the strains in the superior femoral neck are reduced while those in the inferior neck are increased. INTERPRETATION: The study concluded that valgus alignment of the resurfacing arthroplasty is preferential to varus alignment; as it induces a more physiological strain pattern and reduces the risk of femoral neck fracture. These findings are in line with clinical experience, which has shown an increase of failure with varus implanted prostheses.
机译:背景:股骨头表面置换术是年轻的活跃髋关节置换患者的流行手术。尽管当前一代的金属对金属表面置换术已治愈了较早修复表面植入物所困扰的骨溶解问题,但股骨头的骨折和无菌性松动仍是其生存的关键因素。几项研究表明,在将股骨植入内翻角的情况下,股骨重现失败的趋势。这项工作的目的是调查内翻外翻方向对股骨近端重覆表面内负荷转移的影响。方法:本研究使用基于计算机断层扫描的有限元分析来确定植入物方向对股骨近端相对于完整股骨的负荷转移的影响。研究了一组16个股骨,以考虑患者之间的差异。为每个股骨制作了四个模型,其中一个完整的股骨,其中一个用植入物固定在股骨颈上进行了表面翻新,另一个表示内翻与外翻的对齐方式。结果:结果显示外翻对齐的股骨重现表面,产生与完整股骨更相似的应变模式。随着植入物相对于股骨干的角度从内翻到外翻增大,股骨上颈部的应变减少而下颈部的应变增加。解释:研究得出结论,表面置换术的外翻对准优先于内翻对准。因为它会诱发更多的生理应变模式,并降低股骨颈骨折的风险。这些发现与临床经验一致,临床经验表明内翻植入假体的失败率增加。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号