BACKGROUND: Because of its technical feasibility and presumed safety benefits, balloon cryoablation is being increasingly employed for pulmonary vein (PV) isolation. While acute isolation has been demonstrated in most patients, little data are available on the chronic durability of cryoballoon lesions. METHODS AND RESULTS: Twelve atrial fibrillation patients underwent PV isolation using either a 23-mm or 28-mm cryoballoon. For each vein, after electrical isolation was verified with the use of a circular mapping cathether, 2 bonus balloon ablation lesions were placed. Gaps in balloon occlusion were overcome using either a spot cryocatheter or a "pull-down" technique. A prespecified second procedure was performed at 8-12 weeks to assess for long-term PV isolation. Acute PV isolation was achieved in all PVs in the patient cohort (n = 48 PVs), using the cryoballoon alone in 47/48 PVs (98%); a "pull-down" technique was employed for 5 PVs (1 right superior pulmonary vein, 2 right inferior pulmonary veins, and 2 left inferior pulmonary veins). The gap in the remaining vein was ablated with a spot cryocatheter. During the second mapping procedure, 42 of 48 PVs (88%) remained isolated. One vein had reconnected in 2 patients, while 2 veins had reconnected in another 2 patients. All PVs initially isolated with the "pull-down" technique remained isolated at the second procedure. CONCLUSIONS: Cryoballoon ablation allows for durable PV isolation with the use of a single balloon. With maintained chronic isolation in most PVs, it may represent a significant step toward consistent and lasting ablation procedures.
机译:背景:由于其技术可行性和假定的安全性优势,越来越多地采用球囊冷冻消融术来隔离肺静脉(PV)。尽管在大多数患者中已经证明了急性隔离,但是关于冷冻气球病变的长期耐久性的数据很少。方法和结果:12名房颤患者使用23毫米或28毫米冷冻气球进行PV隔离。对于每条静脉,在使用圆形映射导管验证了电隔离之后,放置了2个额外的球囊消融灶。使用点式低温导管或“下拉”技术可克服球囊阻塞的间隙。在8-12周执行了预先指定的第二步程序,以评估长期PV隔离。在患者队列的所有PV中均实现了急性PV隔离(n = 48 PV),仅在47/48 PV中使用冷冻气球(98%)即可; “下拉”技术用于5个PV(1个右上肺静脉,2个右下肺静脉和2个左下肺静脉)。残留的静脉间隙用冷冻导管消融。在第二个映射过程中,仍隔离了48个PV中的42个(88%)。 2例患者的一条静脉重新连接,而另外2例患者的2条静脉重新连接。最初使用“下拉”技术隔离的所有PV在第二步均保持隔离状态。结论:冷冻球消融术允许使用单个球囊实现持久的PV隔离。在大多数PV中保持长期隔离,这可能是朝着一致且持久的消融程序迈出的重要一步。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号